Back to Search Start Over

Study on maintenance of eyeball morphology by foldable capsular vitreous body in severe ocular trauma

Authors :
Shanyu Li
Xiaoxuan Wang
Zhixia Dou
Jie Zhang
Jinchen Jia
Source :
BMC Ophthalmology, Vol 23, Iss 1, Pp 1-9 (2023)
Publication Year :
2023
Publisher :
BMC, 2023.

Abstract

Abstract Objectives To explore the feasibility and safety of using a foldable capsular vitreous body (FCVB) in managing severe ocular trauma and silicone oil-dependent eyes. Methodology This is a retrospective study of 61 ocular trauma patients (61 eyes) who presented to the Department of Eye Emergency, Hebei Eye Hospital from May 1, 2018, to May 31, 2019, including 51 male patients (51 eyes) and 10 female patients (10 eyes) with an average age of 44.98 ± 14.60 years old. The oldest patient was 75 years old, and the youngest was 8 years old. These cases represented 51 eyes with severe eyeball rupture and 10 eyes with severe, complicated ocular trauma, which became silicone oil-dependent after the operation. These patients received FCVB implants, and data regarding their visual acuity, intraocular pressure, changes in eye axis, cornea, retina, and FCVB state were recorded after the operation. Results In all patients, the FCVB was properly positioned and well supported with the retina. All 61 patients cleared a follow-up window of 1–36 months with no reports of important changes in their visual acuity. Among the patients, 91.8% reported normal intraocular pressure, the retinal reattachment rate reached 100%, and the eyeball atrophy control rate reached 100%. There was no report of rupture of the FCVB, allergies to silicone, intraocular infection, intraocular hemorrhage, silicone oil emulsification, or sympathetic ophthalmia. Conclusions Foldable capsular vitreous bodies (FCVBs) designed to mimic natural vitreous bodies are suitable as long-term ocular implants that can provide sustained support for the retina without the need for any special postoperative postures. Their barrier function may effectively prolong the retention time of the tamponade and prevent various complications caused by direct contact of the eye tissues with the tamponade.

Details

Language :
English
ISSN :
14712415 and 60383461
Volume :
23
Issue :
1
Database :
Directory of Open Access Journals
Journal :
BMC Ophthalmology
Publication Type :
Academic Journal
Accession number :
edsdoj.6ca34be97ea49748dc60383461b9edc
Document Type :
article
Full Text :
https://doi.org/10.1186/s12886-023-03209-4