Back to Search
Start Over
Optimization of contrast medium volume for abdominal CT in oncologic patients: prospective comparison between fixed and lean body weight-adapted dosing protocols
- Source :
- Insights into Imaging, Vol 12, Iss 1, Pp 1-9 (2021)
- Publication Year :
- 2021
- Publisher :
- SpringerOpen, 2021.
-
Abstract
- Abstract Background Patient body size represents the main determinant of parenchymal enhancement and by adjusting the contrast media (CM) dose to patient weight may be a more appropriate approach to avoid a patient over dosage of CM. To compare the performance of fixed-dose and lean body weight (LBW)-adapted contrast media dosing protocols, in terms of image quality and parenchymal enhancement. Results One-hundred cancer patients undergoing multiphasic abdominal CT were prospectively enrolled in this multicentric study and randomly divided in two groups: patients in fixed-dose group (n = 50) received 120 mL of CM while in LBW group (n = 50) the amount of CM was computed according to the patient’s LBW. LBW protocol group received a significantly lower amount of CM (103.47 ± 17.65 mL vs. 120.00 ± 0.00 mL, p
Details
- Language :
- English
- ISSN :
- 18694101
- Volume :
- 12
- Issue :
- 1
- Database :
- Directory of Open Access Journals
- Journal :
- Insights into Imaging
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.6de6851b111347cfba67e17b576451d1
- Document Type :
- article
- Full Text :
- https://doi.org/10.1186/s13244-021-00980-0