Back to Search Start Over

Network Coordination between High-Voltage DC and High-Voltage AC Transmission Systems Using Flexible AC Transmission System Controllers

Authors :
Nomihla Wandile Ndlela
Innocent Ewean Davidson
Source :
Energies, Vol 15, Iss 19, p 7402 (2022)
Publication Year :
2022
Publisher :
MDPI AG, 2022.

Abstract

The strategic intent of the African Union is to develop a “Smart Integrated African Electric Power Super Grid” driven by modern tools and advances in high-voltage direct current (HVDC) engineering and flexible alternating current technology systems (FACTS), which is central in supporting Africa’s sustained economic growth and development. The southern African region, including South Africa, is beset by the critical challenges of perennial load-shedding, which impedes economic growth and aggravates unemployment. This has led to the insecurity of electricity supplies and degraded the quality of life. The parallel operation of high-voltage direct current (HVDC) and flexible AC technology systems (FACTS) controllers is gaining traction as system conditions become more complex, such as weak power networks which requires increased stability requirements, resulting in load-shedding and power outages. These adversely affect business productivity and adversely affect GDP and economic growth. Thus, the application of innovative technologies such as HVDC links can stabilize weak power systems. It is established that HVDC delivery systems reduce losses in long transmission lines transporting bulk power compared with high-voltage alternating current (HVAC) transmission lines for power wheeling. This paper evaluates the parallel operation of the Cahora Bassa 1414 km bipolar HVDC link and a weak parallel 400/330 kV alternating current (AC) link. It demonstrates the use of FACTS controllers to enhance the technical performance of an existing network, such as voltage control, and technical loss reduction. It combines an HVDC line commutated converter (LCC) and HVAC transmission lines, in hybrid notation to increase the voltage stability of the system by controlling the reactive power with a Static Var Compensator (SVC). These modern tools can increase the transmission power controllability and stability of the power network. In this study, HVDC–LCC was used with a setpoint of 1000 MW in conjunction with the 850 MVAr SVC. The results show that the technical losses were reduced by 0.24% from 84.32 MW to 60.32 MW as Apollo 275 kV SVC was utilized for voltage control. The network analysis was performed using DIgSILENT PowerFactory software that is manufactured by DIgSILENT GmbH at Gomaringen, Germany

Details

Language :
English
ISSN :
19961073
Volume :
15
Issue :
19
Database :
Directory of Open Access Journals
Journal :
Energies
Publication Type :
Academic Journal
Accession number :
edsdoj.73a3799acfa2403c979f275cd091dfc3
Document Type :
article
Full Text :
https://doi.org/10.3390/en15197402