Back to Search Start Over

Evaluation of endothelial/Descemet membrane complex of eye bank donor corneas using enhanced depth imaging optical coherence tomography

Authors :
Syed ZA
Gameiro GR
Ruggeri M
Elsawy A
Sayed-Ahmed I
Roongpoovapatr V
Abdel-Mottaleb M
Abou Shousha M
Source :
Clinical Ophthalmology, Vol Volume 13, Pp 789-794 (2019)
Publication Year :
2019
Publisher :
Dove Medical Press, 2019.

Abstract

Zeba A Syed,1 Gustavo Rosa Gameiro,1 Marco Ruggeri,1 Amr Elsawy,1,2 Ibrahim Sayed-Ahmed,1 Vatookarn Roongpoovapatr,1 Mohamed Abdel-Mottaleb,2 Mohamed Abou Shousha11Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA; 2Department of Electrical and Computer Engineering, University of Miami College of Engineering, Coral Gables, FL, USAObjective: We present a novel method for screening eye bank donor corneas using high definition optical coherence tomography (HD-OCT). This technology allows for the quantification of endothelial/Descemet membrane (En/DM) complex thickness ex vivo.Design: Prospective interventional study.Participants: Fifty-two corneal grafts from 27 donors were included in this study. Twenty additional control eyes and 11 eyes with Fuchs’ endothelial corneal dystrophy were also evaluated for comparison.Methods: A custom built, high speed HD-OCT device (Envisu R2210, Bioptigen, Buffalo Grove, IL, USA) was used to obtain images, and custom-made graph-based segmentation software was used to automatically deconstruct corneal images into micro-layers. HD-OCT imaging was used to scan through the sealed sterile case of donor corneas stored in McCarey-Kaufman medium to image their En/DM complex through the center of the cornea.Results: This technology allowed for quantification of En/DM complex thickness in all donor corneas through the sealed sterile container used to transport graft tissue. Mean En/DM complex thickness of donor corneas was 17±4 μm. The difference between donor cornea En/DM thickness and that of control subjects (16±2 μm) was not statistically significant (p=0.3), suggesting that the transport container and media do not affect measurements. There was a significant difference between En/DM thickness of Fuchs’ endothelial corneal dystrophy eyes (25±5 μm) and both donor corneas (p

Details

Language :
English
ISSN :
11775483
Volume :
ume 13
Database :
Directory of Open Access Journals
Journal :
Clinical Ophthalmology
Publication Type :
Academic Journal
Accession number :
edsdoj.783ca99219e54b52af1e0a7f7f7daecf
Document Type :
article