Back to Search Start Over

Diagnostic performance of ACR-TIRADS combined with superb microvascular imaging for differential diagnosis of mummified thyroid nodules and papillary thyroid carcinomas

Authors :
Jiali Tian
Jinlei Liang
Yuhong Lin
Liping Wang
Xiaobo Chen
Source :
Endocrine Connections, Vol 13, Iss 3, Pp 1-9 (2024)
Publication Year :
2024
Publisher :
Bioscientifica, 2024.

Abstract

Objective: The aim was to investigate the ability of superb microvascular imaging (SMI) to improve the differential diagnosis of mummified thyroid nodules (MTNs) and papillary thyroid carcinomas (PTCs) using the 2017 American College of Radiology Thyroid Imaging Reporting and Data System (ACR-TIRADS). Materials and methods: We enrolled 110 cases of MTNs and 110 cases of PTCs confirmed by fine needle aspiration (FNA) or surgery. Conventional ultrasound (US) and the quantity of microvessels detected by SMI were analyzed for all nodules. Thyroid nodules were initially categorized by ACR-TIRADS based on US imaging features and then reclassified based on ACR-TIRADS combined with SMI blood-flow grade (SMI-TIRADS). We compared the diagnostic performances of ACR-TIRADS and SMI-TIRADS by receiver operating characteristic curve, sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV). Results: US-detected margin, shape, and echogenic foci differed between MTNs and PTCs (P < 0.05). The SMI blood-flow grade was significantly greater in PTCs compared with MTNs (Χ2 = 158.78, P < 0.05). There was no significant difference in ACR-TIRADS indicators between MTNs and PTCs (Χ2 = 1.585, P = 0.453); however, reclassification by SMI-TIRADS showed significant differences between the groups (Χ2 = 129.521, P < 0.001). The area under the curve was significantly lower for ACR-TIRADS compared with SMI-TIRADS (0.517 vs 0.887, P < 0.05). SMI-TIRADS had significantly higher diagnostic value for distinguishing MTNs and PTCs than ACR-TIRADS (sensitivity: 91.82% vs 74.55%, P < 0.05; specificity: 84.55% vs 21.82%, P < 0.05; accuracy: 88.18% vs 48.18%, P < 0.05; PPV: 85.59% vs 48.81%, P < 0.05; and NPV: 91.18% vs 46.15%, P < 0.05). Conclusion: The detection of microvascular flow and large vessels in thyroid nodules by SMI resulted in high diagnostic specificity and sensitivity. ACR-TIRADS combined with SMI could effectively distinguish between MTNs and PTCs, to avoid unnecessary FNA or surgical excision.

Details

Language :
English
ISSN :
20493614
Volume :
13
Issue :
3
Database :
Directory of Open Access Journals
Journal :
Endocrine Connections
Publication Type :
Academic Journal
Accession number :
edsdoj.7b488dac40d48cea232f5b1f31d6b6d
Document Type :
article
Full Text :
https://doi.org/10.1530/EC-23-0388