Back to Search Start Over

Evaluation of the tumor movement and the reproducibility of two different immobilization setups for image-guided stereotactic body radiotherapy of liver tumors

Authors :
Constantin Dreher
Markus Oechsner
Michael Mayinger
Stefanie Beierl
Marciana-Nona Duma
Stephanie E. Combs
Daniel Habermehl
Source :
Radiation Oncology, Vol 13, Iss 1, Pp 1-7 (2018)
Publication Year :
2018
Publisher :
BMC, 2018.

Abstract

Abstract Background The purpose of this study is to evaluate the tumor movement and accuracy of patient immobilization in stereotactic body radiotherapy of liver tumors with low pressure foil or abdominal compression. Methods Fifty-four liver tumors treated with stereotactic body radiotherapy were included in this study. Forty patients were immobilized by a vacuum couch with low pressure foil, 14 patients by abdominal compression. We evaluated the ratio of gross tumor volume/internal target volume, the tumor movement in 4D-computed tomography scans and daily online adjustments after cone beam computed tomography scans. Results The ratio of gross tumor volume/internal target volume was smaller with low pressure foil. The tumor movement in 4D-computed tomography scans was smaller with abdominal compression, the cranial movement even significantly different (p = 0.02). The mean online adjustments and their mean absolute values in the vertical, lateral and longitudinal axis were smaller with abdominal compression. The online adjustments were significantly different (p

Details

Language :
English
ISSN :
1748717X
Volume :
13
Issue :
1
Database :
Directory of Open Access Journals
Journal :
Radiation Oncology
Publication Type :
Academic Journal
Accession number :
edsdoj.7ba63c4e750440cc8f889636de8288af
Document Type :
article
Full Text :
https://doi.org/10.1186/s13014-018-0962-9