Back to Search Start Over

Computed Tomography Coronary Angiography and Computational Fluid Dynamics Based Fractional Flow Reserve Before and After Percutaneous Coronary Intervention

Authors :
Gaurav Chandola
Jun-Mei Zhang
Ru-San Tan
Ping Chai
Lynette Teo
John C. Allen
Ris Low
Weimin Huang
Shuang Leng
Jiang Ming Fam
Chee Yang Chin
Ghassan S. Kassab
Adrian Fatt Hoe Low
Swee Yaw Tan
Terrance Chua
Soo Teik Lim
Liang Zhong
Source :
Frontiers in Bioengineering and Biotechnology, Vol 9 (2021)
Publication Year :
2021
Publisher :
Frontiers Media S.A., 2021.

Abstract

Invasive fractional flow reserve (FFR) is recommended to guide stent deployment. We previously introduced a non-invasive FFR calculation (FFRB) based on computed tomography coronary angiography (CTCA) with reduced-order computational fluid dynamics (CFD) and resistance boundary conditions. Current study aimed to assess the feasibility and accuracy of FFRB for predicting coronary hemodynamics before and after stenting, with invasive FFR as the reference. Twenty-five patients who had undergone CTCA were prospectively enrolled before invasive coronary angiography (ICA) and FFR-guided percutaneous coronary intervention (PCI) on 30 coronary vessels. Using reduced-order CFD with novel boundary conditions on three-dimensional (3D) patient-specific anatomic models reconstructed from CTCA, we calculated FFRB before and after virtual stenting. The latter simulated PCI by clipping stenotic segments from the 3D coronary models and replacing them with segments to mimic the deployed coronary stents. Pre- and post-virtual stenting FFRB were compared with FFR measured pre- and post-PCI by investigators blinded to FFRB results. Among 30 coronary lesions, pre-stenting FFRB (mean 0.69 ± 0.12) and FFR (mean 0.67 ± 0.13) exhibited good correlation (r = 0.86, p < 0.001) and agreement [mean difference 0.024, 95% limits of agreement (LoA): −0.11, 0.15]. Similarly, post-stenting FFRB (mean 0.84 ± 0.10) and FFR (mean 0.86 ± 0.08) exhibited fair correlation (r = 0.50, p < 0.001) and good agreement (mean difference 0.024, 95% LoA: −0.20, 0.16). The accuracy of FFRB for identifying post-stenting ischemic lesions (FFR ≤ 0.8) (residual ischemia) was 87% (sensitivity 80%, specificity 88%). Our novel FFRB, based on CTCA with reduced-order CFD and resistance boundary conditions, accurately predicts the hemodynamic effects of stenting which may serve as a tool in PCI planning.

Details

Language :
English
ISSN :
22964185
Volume :
9
Database :
Directory of Open Access Journals
Journal :
Frontiers in Bioengineering and Biotechnology
Publication Type :
Academic Journal
Accession number :
edsdoj.7d3852ff060b41f5b68219467bde3ac9
Document Type :
article
Full Text :
https://doi.org/10.3389/fbioe.2021.739667