Impact of the blooming artefact on dental implant dimensions in 13 cone-beam computed tomography devices

Authors :
Victor Aquino Wanderley
Karla de Faria Vasconcelos
Andre Ferreira Leite
Ruben Pauwels
Sohaib Shujaat
Reinhilde Jacobs
Matheus L. Oliveira
Source :
International Journal of Implant Dentistry, Vol 7, Iss 1, Pp 1-10 (2021)
Publication Year :
2021
Publisher :
SpringerOpen, 2021.

Abstract

Abstract Background The purpose of this study was to objectively assess dimensional alteration (blooming artefact) on dental implant using 13 cone-beam computed tomography (CBCT) devices adjusted to device-specific scanning protocols and to assess whether subjective adjustment of brightness and contrast (B&C) could alter its visualization. Methods An anthropomorphic phantom containing a dental implant was scanned in 13 CBCT devices adjusted to three scanning protocols: medium-FOV standard resolution, small-FOV standard resolution, and small-FOV high resolution. The diameter of the implant was measured at five levels, averaged, and compared with those from a reference standard industrial CT image. B&C adjustments were performed and measurements were repeated. The intraclass correlation coefficient assessed the reliability of the measurements and general linear mixed models were applied for multiples comparisons at a 95% confidence interval. Results Implant diameter obtained from small-FOV high-resolution protocols in most CBCT devices was not significantly different when compared to that from the reference (p > 0.05). For standard protocols, significant dimensional alteration of the implant ranging from 23 to 34% (0.67 to 1.02 mm) was observed in 9 CBCT devices for small-FOV scanning (p < 0.05), and in 8 CBCT devices for medium-FOV scanning, implant dimensional alteration ranged significantly from 21 to 35% (0.62 to 1.04 mm). After B&C adjustments, dimensional alteration was reduced for several of the CBCT devices tested (p < 0.05). Conclusions The visualization of the implant dimensional alteration differed between CBCT devices and scanning protocols with an increase in diameter ranging from 0.27 to 1.04 mm. For most CBCT devices, B&C adjustments allowed to reduce visualization of implant blooming.

Details

Language :
English
ISSN :
21984034
Volume :
7
Issue :
1
Database :
Directory of Open Access Journals
Journal :
International Journal of Implant Dentistry
Publication Type :
Academic Journal
Accession number :
edsdoj.864cf49da0f1407fb75087136b08b003
Document Type :
article
Full Text :
https://doi.org/10.1186/s40729-021-00347-6