Back to Search Start Over

Wavelet filtering of fetal phonocardiography: A comparative analysis

Authors :
Selene Tomassini
Annachiara Strazza
Agnese Sbrollini
Ilaria Marcantoni
Micaela Morettini
Sandro Fioretti
Laura Burattini
Source :
Mathematical Biosciences and Engineering, Vol 16, Iss 5, Pp 6034-6046 (2019)
Publication Year :
2019
Publisher :
AIMS Press, 2019.

Abstract

Fetal heart rate (FHR) monitoring can serve as a benchmark to identify high-risk fetuses. Fetal phonocardiogram (FPCG) is the recording of the fetal heart sounds (FHS) by means of a small acoustic sensor placed on maternal abdomen. Being heavily contaminated by noise, FPCG processing implies mandatory filtering to make FPCG clinically usable. Aim of the present study was to perform a comparative analysis of filters based on Wavelet transform (WT) characterized by different combinations of mothers Wavelet and thresholding settings. By combining three mothers Wavelet (4th-order Coiflet, 4th-order Daubechies and 8th-order Symlet), two thresholding rules (Soft and Hard) and three thresholding algorithms (Universal, Rigorous and Minimax), 18 different WT-based filters were obtained and applied to 37 simulated and 119 experimental FPCG data (PhysioNet/PhysioBank). Filters performance was evaluated in terms of reliability in FHR estimation from filtered FPCG and noise reduction quantified by the signal-to-noise ratio (SNR). The filter obtained by combining the 4th-order Coiflet mother Wavelet with the Soft thresholding rule and the Universal thresholding algorithm was found to be optimal in both simulated and experimental FPCG data, since able to maintain FHR with respect to reference (138.7[137.7; 140.8] bpm vs. 140.2[139.7; 140.7] bpm, P > 0.05, in simulated FPCG data; 139.6[113.4; 144.2] bpm vs. 140.5[135.2; 146.3] bpm, P > 0.05, in experimental FPCG data) while strongly incrementing SNR (25.9[20.4; 31.3] dB vs. 0.7[-0.2; 2.9] dB, P < 10-14, in simulated FPCG data; 22.9[20.1; 25.7] dB vs. 15.6[13.8; 16.7] dB, P < 10-37, in experimental FPCG data). In conclusion, the WT-based filter obtained combining the 4th-order Coiflet mother Wavelet with the thresholding settings constituted by the Soft rule and the Universal algorithm provides the optimal WT-based filter for FPCG filtering according to evaluation criteria based on both noise and clinical features.

Details

Language :
English
ISSN :
15510018
Volume :
16
Issue :
5
Database :
Directory of Open Access Journals
Journal :
Mathematical Biosciences and Engineering
Publication Type :
Academic Journal
Accession number :
edsdoj.866a87467dbe413da0d51b2110d50ed4
Document Type :
article
Full Text :
https://doi.org/10.3934/mbe.2019302?viewType=HTML