Back to Search Start Over

Design and Initial Tests of a Fast Neutron Radiography Detector Prototype with Silicon Photomultiplier Readouts

Authors :
Xu Chen
Bin Tang
Ruofu Chen
Zhifu Zhu
Pingchuan Zhang
Qian Yu
Chang Huang
Shaojia Chen
Xiuku Wang
Hong Xu
Xiaojie Cai
Dawei Guo
Li Yu
Zhijia Sun
Yanfeng Wang
Yuntao Liu
Source :
Applied Sciences, Vol 14, Iss 13, p 5536 (2024)
Publication Year :
2024
Publisher :
MDPI AG, 2024.

Abstract

Among non-destructive testing (NDT) techniques, fast neutron radiography with a higher penetration capability has achieved rapid advancements. However, the application of the radiography detector in many fast neutron imaging systems is limited by unfavorable detection efficiency and imaging spatial resolution. In this paper, a fast neutron radiography detector was designed, which was composed of a pixelated EJ200 scintillator array, a 16 × 16 silicon photomultiplier (SiPM) array, and capacitive multiplexing network readout electronics. The main parameters of the detector were optimized using Monte Carlo simulations. In addition, the prototype of the detector was fabricated and tested under a 14 MeV D-T neutron source. The preliminary test results demonstrated that the spatial resolution of the prototype reached 1.2 mm. Moreover, the conflict between spatial resolution and detection efficiency could be mitigated by using a pixelated scintillator structure. Overall, SiPMs enabled the extensive application of the imaging system because of their excellent photon detection performance, relatively low price, and joint possibility for large areas.

Details

Language :
English
ISSN :
20763417
Volume :
14
Issue :
13
Database :
Directory of Open Access Journals
Journal :
Applied Sciences
Publication Type :
Academic Journal
Accession number :
edsdoj.88c1c8db234476893134557f671d778
Document Type :
article
Full Text :
https://doi.org/10.3390/app14135536