Back to Search Start Over

The use of transpulmonary contrast echocardiography: A first experience in Serbia

Authors :
Stojšić-Milosavljević Anastrazija
Ilić Aleksandra
Stojšić Snežana
Ivanović Vladimir
Milićević Jelena
Kovač Robert
Stefanović Maja
Tadić Snežana
Miljković Tatjana
Bjelobrk Marija
Dabović Dragana
Živkov-Šaponja Dragoslava
Petrović Milovan
Aleksandar Redžek
Source :
Vojnosanitetski Pregled, Vol 78, Iss 10, Pp 1036-1045 (2021)
Publication Year :
2021
Publisher :
Military Health Department, Ministry of Defance, Serbia, 2021.

Abstract

Background/Aim. Contrast echocardiography (CE) is an echocardiographic modality where ultrasound contrast echocardiographic agent (CEA) is introduced peripherally for the image enhancement. The aim of this study was to present the initial clinical experience of the use of CEA Optison™ (GE Healthcare, Princeton, NJ) at the Institute for Cardiovascular Diseases of Vojvodina, Serbia and prospectively monitor the occurrence of possible side effects. Methods. A total of 357 patients were referred for resting or stress echocardiographic examinations, with an approved indication for CEA administration. The average age of patients was 63.3 years (range, 21–92 years), 62% of them were men. Most of the patients (77.31%) had some form of ischemic heart diseases. Hypertension was the most frequent risk factor (77.03%), but 57 patients had diabetes mellitus and 33 patients had chronic kidney disease as comorbidity. Most (90.5%) of the patients were on beta blocker therapy, 83.5% of them on angiotensin converting enzyme/angiotensin receptor blockers. Majority (80.3%) of the patients received single or dual (49.5%) antiagregation therapy, 74 (26.3%), of them were on anticoagulation therapy, 55.1% of the patients were taking diuretics. The global ejection fraction (EF) was preserved in 39.85% of them, the majority (136 of them), had left ventricle (LV) impairment, with an EF less than 50%. Patients were followed up for 30 minutes after CEA administration for potential side effects. In 118 patients, vital signs (heart rate, oxygen saturation, body temperature, systolic and diastolic blood pressure) were measured before and 30 minutes after CEA administration. Results. The administration of CEA was not associated with side effects. Diastolic blood pressure drop and heart rate increase were statistically, but not clinically significant (p = 0.027 and p = 0.028, respectively). Conclusion. Changes in analyzed vital signs were clinically non relevant. CE is a safe noninvasive diagnostic modality for patients undergoing rest and stress echocardiography.

Details

Language :
English, Serbian
ISSN :
00428450 and 24060720
Volume :
78
Issue :
10
Database :
Directory of Open Access Journals
Journal :
Vojnosanitetski Pregled
Publication Type :
Academic Journal
Accession number :
edsdoj.8cc6d75e21a24e79b95294a74de989d0
Document Type :
article
Full Text :
https://doi.org/10.2298/VSP190127020S