Back to Search Start Over

Comparison of Machine-Learning and Deep-Learning Methods for the Prediction of Osteoradionecrosis Resulting From Head and Neck Cancer Radiation Therapy

Authors :
Brandon Reber, BS
Lisanne Van Dijk, PhD
Brian Anderson, PhD
Abdallah Sherif Radwan Mohamed, MD, PhD
Clifton Fuller, MD, PhD
Stephen Lai, MD, PhD
Kristy Brock, PhD
Source :
Advances in Radiation Oncology, Vol 8, Iss 4, Pp 101163- (2023)
Publication Year :
2023
Publisher :
Elsevier, 2023.

Abstract

Purpose: Deep-learning (DL) techniques have been successful in disease-prediction tasks and could improve the prediction of mandible osteoradionecrosis (ORN) resulting from head and neck cancer (HNC) radiation therapy. In this study, we retrospectively compared the performance of DL algorithms and traditional machine-learning (ML) techniques to predict mandible ORN binary outcome in an extensive cohort of patients with HNC. Methods and Materials: Patients who received HNC radiation therapy at the University of Texas MD Anderson Cancer Center from 2005 to 2015 were identified for the ML (n = 1259) and DL (n = 1236) studies. The subjects were followed for ORN development for at least 12 months, with 173 developing ORN and 1086 having no evidence of ORN. The ML models used dose-volume histogram parameters to predict ORN development. These models included logistic regression, random forest, support vector machine, and a random classifier reference. The DL models were based on ResNet, DenseNet, and autoencoder-based architectures. The DL models used each participant's dose cropped to the mandible. The effect of increasing the amount of available training data on the DL models’ prediction performance was evaluated by training the DL models using increasing ratios of the original training data. Results: The F1 score for the logistic regression model, the best-performing ML model, was 0.3. The best-performing ResNet, DenseNet, and autoencoder-based models had F1 scores of 0.07, 0.14, and 0.23, respectively, whereas the random classifier's F1 score was 0.17. No performance increase was apparent when we increased the amount of training data available for DL model training. Conclusions: The ML models had superior performance to their DL counterparts. The lack of improvement in DL performance with increased training data suggests that either more data are needed for appropriate DL model construction or that the image features used in DL models are not suitable for this task.

Details

Language :
English
ISSN :
24521094
Volume :
8
Issue :
4
Database :
Directory of Open Access Journals
Journal :
Advances in Radiation Oncology
Publication Type :
Academic Journal
Accession number :
edsdoj.8de3d5b32ac343cca629c88b5409c8d8
Document Type :
article
Full Text :
https://doi.org/10.1016/j.adro.2022.101163