Back to Search Start Over

A simple solution to unexpected kinking of endotracheal tube

Authors :
Mansoor Aqil
Abdulhamid Al-Saeed
Source :
Saudi Journal of Anaesthesia, Vol 7, Iss 3, Pp 344-346 (2013)
Publication Year :
2013
Publisher :
Wolters Kluwer Medknow Publications, 2013.

Abstract

We report a case of unexpected kinking of endotracheal (ET) tube in an infant who was being operated in supine position and positioned away from the anesthetist. The usual management mentioned in the literature was unsuccessful. So, a simple and unique solution that can be useful in unanticipated kinking of ET tube is described.

Details

Language :
English
ISSN :
1658354X
Volume :
7
Issue :
3
Database :
Directory of Open Access Journals
Journal :
Saudi Journal of Anaesthesia
Publication Type :
Academic Journal
Accession number :
edsdoj.96e9809030a4f52b84851f2f50f62f8
Document Type :
article
Full Text :
https://doi.org/10.4103/1658-354X.115333