Back to Search Start Over

O-RADS combined with contrast-enhanced ultrasound in risk stratification of adnexal masses

Authors :
Yanyun Shi
Huan Li
Xiuhua Wu
Xiaoqin Li
Min Yang
Source :
Journal of Ovarian Research, Vol 16, Iss 1, Pp 1-8 (2023)
Publication Year :
2023
Publisher :
BMC, 2023.

Abstract

Abstract Background Ovarian-Adnexal Reporting and Data System (O-RADS) for ultrasound is a lexicon and risk stratification system that includes all risk categories and relevant management recommendation. It has high sensitivity in diagnosing malignant adnexal tumors, but the specificity is lower. Objective To explore the value of O-RADS combined with contrast-enhanced ultrasound (CEUS) in risk stratification of adnexal masses. Methods A retrospective study was performed on 85 patients with 100 adnexal masses that preoperatively underwent conventional ultrasound as well as CEUS examination and obtained the postoperative pathological results. The masses were classified into O-RADS2, 3, 4, and 5 by conventional ultrasound. After contrast enhancement, the classification of O-RADS was adjusted according to CEUS imaging features. The O-RADS 2 and 3 lesions with suspected malignant features like irregular blood vessels or internal inhomogeneous hyperenhancement were upgraded to O-RADS 4, and the O-RADS 4 lesions with the above features were upgraded to O-RADS 5. The O-RADS 4 lesions with suspicious benign angiographic features like a regular vessel, interior hypoenhancement or non-enhancement were downgraded to O-RADS 3; the O-RADS 5 lesions with rim ring-enhancement and interior non-enhancement were downgraded to O-RADS 3. The sensitivity, specificity, accuracy, PPV, NPV, and AUC of the two methods were compared, taking pathological results as the gold standard. Results The sensitivity, specificity, accuracy, PPV, NPV, and AUC of O-RADS and O-RADS combined with CEUS in the diagnosis of malignant adnexal tumors were 96.6%, 66.2%, 75.0%, 53.8%, 97.9%, 0.910 and 96.6%, 91.5%, 93.0%, 82.4%, 98.5%, 0.962, respectively. The specificity, accuracy, PPV, and AUC of O-RADS combined with CEUS were considerably higher than those of O-RADS (P 0.05). Conclusion Combination of O-RADS and CEUS can significantly improve the specificity and PPV in diagnosing malignant adnexal tumors. It seems promising in the clinical application of risk stratification of adnexal masses.

Details

Language :
English
ISSN :
17572215
Volume :
16
Issue :
1
Database :
Directory of Open Access Journals
Journal :
Journal of Ovarian Research
Publication Type :
Academic Journal
Accession number :
edsdoj.9a83a286395b4ddc8d550c57dd4b20fa
Document Type :
article
Full Text :
https://doi.org/10.1186/s13048-023-01243-w