Back to Search Start Over

Quantification of carotid plaque composition with a multi-contrast atherosclerosis characterization (MATCH) MRI sequence

Authors :
Mohamed Kassem
Kelly P. H. Nies
Ellen Boswijk
Jochem van der Pol
Mueez Aizaz
Marion J. J. Gijbels
Debiao Li
Jan Bucerius
Werner H. Mess
Joachim E. Wildberger
Robert J. van Oostenbrugge
Rik P. M. Moonen
Zhaoyang Fan
M. Eline Kooi
Source :
Frontiers in Cardiovascular Medicine, Vol 10 (2023)
Publication Year :
2023
Publisher :
Frontiers Media S.A., 2023.

Abstract

Background and purposeCarotid atherosclerotic plaques with a large lipid-rich necrotic core (LRNC), intraplaque hemorrhage (IPH), and a thin or ruptured fibrous cap are associated with increased stroke risk. Multi-sequence MRI can be used to quantify carotid atherosclerotic plaque composition. Yet, its clinical implementation is hampered by long scan times and image misregistration. Multi-contrast atherosclerosis characterization (MATCH) overcomes these limitations. This study aims to compare the quantification of plaque composition with MATCH and multi-sequence MRI.MethodsMATCH and multi-sequence MRI were used to image 54 carotid arteries of 27 symptomatic patients with ≥2 mm carotid plaque on a 3.0 T MRI scanner. The following sequence parameters for MATCH were used: repetition time/echo time (TR/TE), 10.1/4.35 ms; field of view, 160 mm × 160 mm × 2 mm; matrix size, 256 × 256; acquired in-plane resolution, 0.63 mm2× 0.63 mm2; number of slices, 18; and flip angles, 8°, 5°, and 10°. Multi-sequence MRI (black-blood pre- and post-contrast T1-weighted, time of flight, and magnetization prepared rapid acquisition gradient echo; acquired in-plane resolution: 0.63 mm2 × 0.63 mm2) was acquired according to consensus recommendations, and image quality was scored (5-point scale). The interobserver agreement in plaque composition quantification was assessed by the intraclass correlation coefficient (ICC). The sensitivity and specificity of MATCH in identifying plaque composition were calculated using multi-sequence MRI as a reference standard.ResultsA significantly lower image quality of MATCH compared to that of multi-sequence MRI was observed (p

Details

Language :
English
ISSN :
2297055X
Volume :
10
Database :
Directory of Open Access Journals
Journal :
Frontiers in Cardiovascular Medicine
Publication Type :
Academic Journal
Accession number :
edsdoj.b0abbdc8a054868b07aeac00e134143
Document Type :
article
Full Text :
https://doi.org/10.3389/fcvm.2023.1227495