An Assessment of the Mechanical Deformation Behavior of Three Different Clear Aligner Materials: A Digital Image Correlation Analysis

An Assessment of the Mechanical Deformation Behavior of Three Different Clear Aligner Materials: A Digital Image Correlation Analysis

Authors :
Nicolae Daniel Olteanu
Camelia Szuhanek
Sorana Nicoleta Rosu
Dragos Florin Chitariu
Nicolae Seghedin
Tinela Panaite
Amalia Casalean
Irina Nicoleta Zetu
Source :
Applied Sciences, Vol 14, Iss 17, p 7496 (2024)
Publication Year :
2024
Publisher :
MDPI AG, 2024.

Abstract

Introduction: The present study aimed to investigate the deformation behavior of three different clear aligner systems, CA® Pro+ Clear Aligner (Scheu Dental, Iserlohn, Germany), Taglus Premium (Taglus Company, Mumbai, India), and Spark Trugen (Ormco Corp., Orange, CA, USA), under compression testing, using the digital image correlation (DIC) technique. Materials and Methods: A total of 15 patients were treated with each of the three aligner systems, resulting in 45 sets of aligners. Each aligner set was fixed on the 3D-printed dental arches and then in an articulator. Then, the samples were subjected to occlusal forces using a purpose-built test stand to allow for controlled force application and precise displacement determination. The DIC technique was used for capturing the deformation behavior, providing detailed strain and displacement fields. Statistical analysis was performed using one-way ANOVA and Bonferroni post hoc tests with a significance of 0.05. Results: The results indicate that the Spark system exhibited the most substantial rigid displacement. Furthermore, the elastic deformation values of the Spark and Taglus systems were significantly higher than those of the CA Pro+ system (p > 0.05). Conclusions: The Spark Trugen clear aligner system demonstrated a lower stability to rigid displacement and elastic deformation under compression testing compared to the Scheu CA® Pro+ Clear Aligner and Taglus Premium. All three tested clear aligner systems showed an increased resistance to elastic displacement and rigid deformation in the mandibular arch.

Details

Language :
English
ISSN :
20763417
Volume :
14
Issue :
17
Database :
Directory of Open Access Journals
Journal :
Applied Sciences
Publication Type :
Academic Journal
Accession number :
edsdoj.b4c06ee165014affb28294c8a52cb4f9
Document Type :
article
Full Text :
https://doi.org/10.3390/app14177496