Prediction of degree of carotid stenosis with the transluminal attenuation difference ratio
- Source :
- Diagnostic and Interventional Radiology, Vol 26, Iss 3, Pp 249-254 (2020)
- Publication Year :
- 2020
- Publisher :
- Galenos Publishing House, 2020.
-
Abstract
- PURPOSEWe aimed to assess the diagnostic performance of transluminal attenuation difference (TAD) in predicting the severity of internal carotid artery (ICA) stenosis.METHODSThe study cohort consisted of 48 patients with 70%) stenosis compared with control arteries and low-moderate stenosis. A TAD ratio cutoff of 4.5 predicted 70%–99% stenosis with a sensitivity of 100% and specificity of 93%. The inter- and intraobserver agreements in TAD measurements were almost perfect (ICC, 0.89–0.86).CONCLUSIONAssessment of TAD ratio predicts the degree of stenosis in concordance with NASCET system.
- Subjects :
- Medical physics. Medical radiology. Nuclear medicine
R895-920
Subjects
Details
- Language :
- English
- ISSN :
- 13053825 and 13053612
- Volume :
- 26
- Issue :
- 3
- Database :
- Directory of Open Access Journals
- Journal :
- Diagnostic and Interventional Radiology
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.b900cadaa3e74f39abec8ad3d27dbc8e
- Document Type :
- article
- Full Text :