Experimental Study on the Influence of the Water Temperature to the Performance of CO2 Heat Pump Water Heater

Authors :
Lv Jing
Ren Yingying
Yang Jie
Dou Junjun
Hu Tete
Source :
Zhileng xuebao, Vol 33 (2012)
Publication Year :
2012
Publisher :
Journal of Refrigeration Magazines Agency Co., Ltd., 2012.

Abstract

The performance of CO2 heat pump water heater was studied experimentally in this paper by comparing a loop heating and a direct heating hot water. In the loop heating mode, with an increase of the water temperature, the compressor inlet and exhaust pressure increased gradually, the power consumption increased and the gas cooler inlet and outlet temperature increased, too. The temperature difference between carbon dioxide and cooling water and heat transfer decreased, the COP of CO2 heat pump system decreased. The operating parameters of the system were stable and the COP remained unchanged in direct heated condition. When the water temperature is 17℃, the COP of the system is about 3.5, much higher than that in loop heating. The results show that the lower inlet temperature can be obtained by modifying the water tank structure and it is a very effective way to improve system performance.

Details

Language :
Chinese
ISSN :
02534339
Volume :
33
Database :
Directory of Open Access Journals
Journal :
Zhileng xuebao
Publication Type :
Academic Journal
Accession number :
edsdoj.baeef150087c4a22a8c1ad91ea46b9b4
Document Type :
article
Full Text :
https://doi.org/10.3969/j.issn.0253-4339.2012.06.073