Stereotactic body radiation therapy (SBRT) for prostate cancer: Improving treatment delivery efficiency and accuracy

Authors :
Edoardo Mastella
Joel E. Epile
Eleonora De Guglielmo
Sara Fabbri
Francesca Calderoni
Luigi Manco
Klarisa E. Szilagyi
Antonio Malorgio
Alessandro Turra
Antonio Stefanelli
Source :
Technical Innovations & Patient Support in Radiation Oncology, Vol 30, Iss , Pp 100253- (2024)
Publication Year :
2024
Publisher :
Elsevier, 2024.

Abstract

Purpose: In stereotactic body radiation therapy (SBRT) for prostate cancer, intrafraction motion is an important source of treatment uncertainty as it could not be completely smoothed through fractionation. Herein, we compared different arrangements and beam qualities for extreme hypofractionated treatments to minimize beam delivery time and so intrafractional errors. Methods: A retrospective dataset of 11 patients was used. Three volumetric modulated arc therapy (VMAT) beam arrangements were compared for a prescription dose of 40 Gy/5 fractions: two full arcs, 6 MV flattening filter free (FFF); one full arc, 6 MV FFF; one full arc, 10 MV FFF. A plan quality index was defined to compare achievement of the planning goals. Plan complexity was evaluated with the modulation factor. Dose delivery accuracy and efficiency were measured with patient-specific quality assurance plans. Results: All treatment plans fulfilled all dose objectives. No statistical differences were found both in plan quality and complexity. Very accurate dose delivery was achieved with the three arrangements, with mean γ passing rates >96.5 % (2 %/2 mm criteria). Slightly but significantly higher γ passing rates were observed with single-arc 6 MV FFF. Contrariwise, statistically significant reductions of the delivery time were obtained with single-arc geometries: the average delivery times were 1.6 min (−46.1 %) and 1.3 min (−56.2 %) for 6 and 10 MV FFF respectively. Conclusions: The high-quality, very fast and accurate dose delivery of single-arc plans confirmed the suitability of this arrangement for prostate SBRT. In particular, the significant reduction of delivery time would improve treatment robustness against intrafraction prostate motion.

Details

Language :
English
ISSN :
24056324
Volume :
30
Issue :
100253-
Database :
Directory of Open Access Journals
Journal :
Technical Innovations & Patient Support in Radiation Oncology
Publication Type :
Academic Journal
Accession number :
edsdoj.bbb6ff3570f443d59774fe4c4afa124e
Document Type :
article
Full Text :