Back to Search Start Over

MISTRAL campaign in support of W7-X long pulse operation

Authors :
Oosterbeek Johan W.
Stern Mathias
Braune Harald
Ewert Karsten
Hirsch Matthias
Hollmann Frank
Killinger Andreas
Laqua Heinrich P.
Maquet Philippe
Marsen Stefan
Martínez-García Venancio
Moseev Dmitry
Noke Frank
Pak Sunil
Reintrog Arne
Stange Torsten
Wolf Robert C.
Zubieta-Lupo Rafael J.
Source :
EPJ Web of Conferences, Vol 277, p 04009 (2023)
Publication Year :
2023
Publisher :
EDP Sciences, 2023.

Abstract

Following two initial campaigns [1], Stellarator Wendelstein 7-X (W7-X) has now completed the construction phase by installation of active cooling of all plasma facing components. The machine is presently commissioned for the next campaign (OP2) aiming at 1 GJ per pulse, e.g. 100 s at 10 MW, eventually aiming at 18 GJ, e.g. 1800 s at 10 MW. The key heating system is the Electron Cyclotron Resonance Heating (ECRH) system, consisting of 10 gyrotrons with power per gyrotron ranging from 0.6 MW up to 1.0 MW at 140 GHz. A phased upgrade of the installation is in progress with the addition of 2 gyrotrons and the development of 1.5 MW and 2.0 MW gyrotrons, such that at the end of the upgrade 4 gyrotrons will be available in each power class of 1.0, 1.5 and 2.0 MW [2]. The increased ECRH power, combined with O2 and X3 heating schemes at high densities, will lead to increased microwave stray radiation. This is non-absorbed microwave power that diffuses inside the vessel and is incident on all in-vessel components including vacuum windows and attached diagnostic systems. A fraction of the stray radiation is absorbed by resistive or dielectric losses of these components, leading to thermal loads that scale with stray radiation levels and pulse length. At W7-X a high power microwave stray radiation launch facility ’MISTRAL’ is available that is used to qualify invessel components for use at specified microwave surface power densities [Wm−2]. This paper reports on MISTRAL campaigns in 2020 2021 for testing of stray radiation loads during OP2 in W7-X, as well as on an EUROfusion program assessing stray radiation loads on ITER components. A dedicated, absolutely calibrated, caloric load was developed for the campaign to obtain measurement of stray radiation power levels as well as to conveniently expose samples. Amongst other we report on shielding concepts using metal enclosures combined with microwave absorbing coatings and dielectric heating of vacuum windows.

Subjects

Subjects :
Physics
QC1-999

Details

Language :
English
ISSN :
2100014X
Volume :
277
Database :
Directory of Open Access Journals
Journal :
EPJ Web of Conferences
Publication Type :
Academic Journal
Accession number :
edsdoj.bed59d38f7a64102849d7802590bccf2
Document Type :
article
Full Text :
https://doi.org/10.1051/epjconf/202327704009