Back to Search Start Over

One-year clinical outcomes of patients with versus without acute coronary syndrome with 3-month duration of dual antiplatelet therapy after everolimus-eluting stent implantation.

Authors :
Masahiro Natsuaki
Takeshi Morimoto
Erika Yamamoto
Hirotoshi Watanabe
Yutaka Furukawa
Mitsuru Abe
Koichi Nakao
Tetsuya Ishikawa
Kazuya Kawai
Kei Yunoki
Shogo Shimizu
Masaharu Akao
Shinji Miki
Masashi Yamamoto
Hisayuki Okada
Kozo Hoshino
Kazushige Kadota
Yoshihiro Morino
Keiichi Igarashi Hanaoka
Kengo Tanabe
Ken Kozuma
Takeshi Kimura
STOPDAPT trial investigators
Source :
PLoS ONE, Vol 15, Iss 3, p e0227612 (2020)
Publication Year :
2020
Publisher :
Public Library of Science (PLoS), 2020.

Abstract

There has been no previous prospective study evaluating 3-month dual antiplatelet therapy (DAPT) after cobalt-chromium everolimus-eluting stent (CoCr-EES) implantation in patients with acute coronary syndrome (ACS). The STOPDAPT trial is a prospective multi-center single-arm study evaluating 3-month DAPT duration in all-comer population after CoCr-EES implantation. Among 1525 study patients enrolled from 58 Japanese centers, the present study compared the 1-year clinical outcomes between ACS patients (N = 487) and stable coronary artery disease (CAD) patients (N = 1038). In the ACS group, 228 patients (47%) had unstable angina and 259 patients (53%) had myocardial infarction. The primary endpoint was a composite of cardiovascular death, myocardial infarction, stroke, definite stent thrombosis (ST) and TIMI major/minor bleeding. Thienopyridine was discontinued within 4-month in 455 patients (94.0%) in the ACS group and 977 patients (94.3%) in the stable CAD group. Cumulative 1-year incidence of and the adjusted risk for the primary endpoint were not significantly different between the ACS and stable CAD groups (2.3% vs. 3.0%, P = 0.42, and HR 0.94, 95%CI 0.44-1.87, P = 0.87). In the 3-month landmark analysis, cumulative incidence of the primary endpoint was also not significantly different between the ACS and stable CAD groups (1.3% vs. 2.4%, P = 0.16). There was no definite/probable ST through 1-year in both groups. In the propensity matched analysis, the cumulative 1-year incidence of the primary endpoint were similar between the ACS and stable CAD groups (2.3% versus 2.1%, P = 0.82). In conclusion, stopping DAPT at 3 months after CoCr-EES implantation in patients with ACS including 47% of unstable angina was as safe as that in patients with stable CAD.

Subjects

Subjects :
Medicine
Science

Details

Language :
English
ISSN :
19326203
Volume :
15
Issue :
3
Database :
Directory of Open Access Journals
Journal :
PLoS ONE
Publication Type :
Academic Journal
Accession number :
edsdoj.bfa867a4f3422a9b48c12eb7f0132f
Document Type :
article
Full Text :
https://doi.org/10.1371/journal.pone.0227612