Back to Search Start Over

A modified XY model of transformer oil–paper insulation system including non‐uniform aging and conductance effect

Authors :
Xianhao Fan
Jiefeng Liu
Yiyi Zhang
Shichang Yang
Chaohai Zhang
Yubo Zhang
Source :
IET Generation, Transmission & Distribution, Vol 15, Iss 13, Pp 2008-2017 (2021)
Publication Year :
2021
Publisher :
Wiley, 2021.

Abstract

Abstract The accuracy and feasibility of the traditional XY model of transformer oil–paper insulation system are disputable since it ignored the effect of non‐uniform aging and conductance on dielectric response property. Given this issue, this work attempted to report a modified XY model to overcome these defects. The novelty of this work is in the exploration of the modified XY model as a potential tool for establishing the quantitative correlation among the complex relative permittivity of the liquid insulation, solid insulation, and liquid–solid composite insulation. In that respect, the presented verification experiments proved the feasibility and accuracy of the reported model. The contributions are expected to provide a theoretical basis for the condition evaluation of transformer solid insulation under non‐uniform aging conditions.

Details

Language :
English
ISSN :
17518695 and 17518687
Volume :
15
Issue :
13
Database :
Directory of Open Access Journals
Journal :
IET Generation, Transmission & Distribution
Publication Type :
Academic Journal
Accession number :
edsdoj.f19710c7141460cb4c7139b56160000
Document Type :
article
Full Text :
https://doi.org/10.1049/gtd2.12168