Back to Search Start Over

The Hysteresis Behavior of Steel Beam–Column Joint with the Load Bearing-Energy Dissipation Connection for Converter Station Building

Authors :
Xian Gao
Shaoyuan Lin
Ruyue Liu
Xilong Chen
Source :
Buildings, Vol 14, Iss 8, p 2424 (2024)
Publication Year :
2024
Publisher :
MDPI AG, 2024.

Abstract

Prefabricated converter station building has been gradually applied in the field of power engineering construction due to the advantages of standardized design, high construction efficiency, and quality control. The beam–column joint is the essential constitutive part to ensure structural integrity and reliable force transmission for the prefabricated structure. In this paper, a novel load bearing-energy dissipation connection is proposed and applied to the beam–column joint to improve seismic performance and seismic resilience. Pseudo-static tests were conducted on the beam–column joint with the load bearing-energy dissipation connection, and the test results demonstrated that the tested beam–column joints developed with similar failure modes, and the damage was concentrated in the load bearing-energy dissipation connection while the beam and column remained elastic. The beam–column joint with the load bearing-energy dissipation connection had stable hysteresis behavior, with favorable bearing capacity and energy dissipation behavior. A shorter slip length and a larger bolt distance could lead to better stress development and enhance the bearing capacity, while the slip length barely affected the ductile behavior. Moreover, a finite element model was established and validated to extend the parametric study to provide a preliminary understanding of the mechanical mechanism of the proposed beam–column joint with the load bearing-energy dissipation connection. It was confirmed that the load–-deformation behavior was greatly affected by the slip length, but the slip length barely affected the initial stiffness. The width of the sliding steel fuse influenced the bearing capacity and the degradation behavior. A wider width could lead to a higher bearing capacity and improve the degradation behavior. Based on the analysis of the stress development and stress distribution corresponding to different feature points, it was concluded that the use of bearing-energy dissipation improved the stress development in the framing components and achieved damage concentration.

Details

Language :
English
ISSN :
20755309
Volume :
14
Issue :
8
Database :
Directory of Open Access Journals
Journal :
Buildings
Publication Type :
Academic Journal
Accession number :
edsdoj.f1c1af1a001f41ff9b5db950c9ba4546
Document Type :
article
Full Text :
https://doi.org/10.3390/buildings14082424