Predictors of Procedural Success in Patients With Degenerated Surgical Valves Undergoing Transcatheter Aortic Valve-in-Valve Implantation

Authors :
Abdelrahman I. Abushouk
Omar Abdelfattah
Anas Saad
Toshiaki Isogai
Medhat Farwati
James Yun
Zoran Popovic
Shashank Shekhar
Rishi Puri
Grant W. Reed
Amar Krishnaswamy
Samir R. Kapadia
Source :
Frontiers in Cardiovascular Medicine, Vol 8 (2021)
Publication Year :
2021
Publisher :
Frontiers Media S.A., 2021.

Abstract

Background: Valve-in-Valve transcatheter aortic valve implantation (ViV-TAVI) is a growing alternative for redo-surgery in patients with degenerated surgical valves. To our knowledge, data are lacking on the determinants on ViV-TAVI procedural success in patients with degenerated surgical valves.Methods: All consecutive patients undergoing ViV-TAVI for degenerated surgical valves at the Cleveland Clinic were analyzed. Data were extracted from our patient registry on baseline patient characteristics, echocardiographic parameters, and procedural details. To identify possible predictors of ViV-TAVI procedural success, we employed a multivariate logistic regression model.Results: A total of 186 patients who underwent ViV-TAVI were analyzed, with procedural success (VARC-2 device success and absence of periprocedural MACCE) reported in 165 (88.7%) patients. Patients with successful ViV-TAVI were significantly younger and had more frequent utilization of the transfemoral access than those with failed procedure. Other baseline and procedural characteristics were comparable between both groups. In terms of echocardiographic parameters, the procedural success group had a significantly lower AV peak pressure gradient (62.1 ± 24.7 vs. 74.1 ± 34.6 mmHg; p = 0.04) and lower incidence of moderate-to-severe aortic regurgitation [AR] (30.4 vs. 55%; p = 0.04). However, no significant differences between both groups were noted in terms of AV mean pressure gradient and left ventricular measurements. In multivariate analysis, lower AV peak pressure gradient (OR = 0.97, 95% CI: 0.95–0.99) and absence of moderate-to-severe AR (OR = 0.65, 95% CI: 0.44–0.95) at baseline emerged as independent predictors of ViV-TAVI procedural success.Conclusion: Valve-in-Valve TAVI for degenerated surgical valves is a feasible approach with high success rates, especially in those with lower AV peak pressure gradient and absence of moderate-to-severe AR. Studies with larger sample size and longer follow-up are required to further characterize the predictors of ViV-TAVI success and other clinical outcomes.

Details

Language :
English
ISSN :
2297055X
Volume :
8
Database :
Directory of Open Access Journals
Journal :
Frontiers in Cardiovascular Medicine
Publication Type :
Academic Journal
Accession number :
edsdoj.f33b0f22aecf4fb1ba03b9b3c3df6215
Document Type :
article
Full Text :
https://doi.org/10.3389/fcvm.2021.718835