Evaluation of optic disc size in patients with optic nerve head drusen using fundus photography
- Source :
- Journal of Optometry, Vol 6, Iss 2, Pp 75-79 (2013)
- Publication Year :
- 2013
- Publisher :
- Elsevier, 2013.
-
Abstract
- Purpose: To evaluate if fundus photography is useful to study the size of the optic disc in patients with optic nerve head drusen (ONHD). Methods: Cross-sectional study. Fifty-five patients with ONHD confirmed by B-scan echography and 52 patients’ normal controls were studied. Fundus photography was done in all the cases with a telecentric optical system FF450 IR plus from Zeiss with 20° magnification and Visupac measuring system. We measured total optic disc area, vertical and horizontal diameter. Results: Patients with ONHD had smaller optic disc area 2.6 ± 0.55 mm2 (mean ± SD), horizontal diameter (1.68 ± 0.18 mm) and vertical diameter (1.94 ± 0.28 mm) than normal controls (2.93 ± 0.43 mm2, 1.86 ± 0.14 mm and 1.98 ± 0.17 mm, respectively). Significant differences were found in area (p = 0.002) and horizontal diameter (p
Details
- Language :
- English
- ISSN :
- 18884296 and 63914859
- Volume :
- 6
- Issue :
- 2
- Database :
- Directory of Open Access Journals
- Journal :
- Journal of Optometry
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.f348e24ec9bf4e4eb4a6391485912651
- Document Type :
- article
- Full Text :
- https://doi.org/10.1016/j.optom.2012.07.003