Back to Search Start Over

Isokinetic Dynamometer Leg Extensor Peak Torque Measurement: A Time-Delayed Reliability and Score Selection Analysis Study

Authors :
Brennan J. Thompson
Jennifer Xu
Source :
Journal of Functional Morphology and Kinesiology, Vol 8, Iss 2, p 62 (2023)
Publication Year :
2023
Publisher :
MDPI AG, 2023.

Abstract

The reliability of isokinetic peak torque (PT) has been reported mostly using a short-term (p ≤ 0.05) than those that involved sets two and three. Systematic error (p ≤ 0.05) was shown for 6 out of the 17 PT selection variables. On a subjective interpretation basis, when taking everything into account the best overall combination of time/trial efficiency, reliability, best/highest PT score parameter, and reduced risk of systematic bias appears to be the PT variable that uses the average of the highest two reps of the first two sets of three reps—i.e., averaging the highest two values of the six total reps from the first two sets.

Details

Language :
English
ISSN :
24115142
Volume :
8
Issue :
2
Database :
Directory of Open Access Journals
Journal :
Journal of Functional Morphology and Kinesiology
Publication Type :
Academic Journal
Accession number :
edsdoj.f3b10eaca05f41a98e071f4721d8068f
Document Type :
article
Full Text :
https://doi.org/10.3390/jfmk8020062