Back to Search Start Over

Abstract 007: Device‐related Technical Complications with Flow Diversion of Intracranial Aneurysms: A Systematic Review and Meta‐analysis

Authors :
Santiago Ortega‐Gutierrez
Aaron Rodriguez‐Calienes
Juan Vivanco‐Suarez
Mahmoud Dibas
Ricardo A. Hanel
Saruhan Cekirge
Saleh Lamih
Hal Rice
Isil Saatci
David Fiorella
Pedro Lylyk
Ivan Lylyk
Vitor Mendes Pereira
Matt Gounis
Jens Fiehler
Source :
Stroke: Vascular and Interventional Neurology, Vol 3, Iss S2 (2023)
Publication Year :
2023
Publisher :
Wiley, 2023.

Abstract

Introduction Flow diverters (FD) have become a revolutionary approach in the endovascular treatment of intracranial aneurysms (IAs), supplanting traditional methods (1). Despite their demonstrated efficacy and safety, unforeseeable device‐related technical complications, such as fish‐mouthing, device braid narrowing, deformation, ovalization, and collapsing have been reported during implantation and follow‐up (2,3,4). However, the definitions and reporting of these complications remain inconsistent. We conducted a systematic review and meta‐analysis to assess overall device‐related technical complication rates associated with flow diversion and provide an overview of the current reported definitions. Methods We searched six databases up to April 4th, 2023, and included studies that reported device‐related technical complications related to FD treatment for IAs. We considered five main outcome measures as device‐related technical complications: (1) fish‐mouthing, (2) device braid collapsing, (3) device braid narrowing, (4) device braid deformation, and (5) device braid ovalization. The data from these studies were pooled using a random‐effects model. Results We included 48 studies involving 3,572 patients and 3,939 aneurysms. Among them, 14 studies (39%) provided definitions for fish‐mouthing. However, none of the included studies offered specific definitions for device braid collapsing, narrowing, or deformation, despite reporting rates for these complications in five, six, and three studies, respectively. The pooled rates for device‐related technical complications were as follows: 3% (95% CI 2 – 4%; I2 = 27%) for fish‐mouthing, 1% (95% CI 0 – 3%; I2 = 0%) for collapsing, 7% (95% CI 2 – 20%; I2 = 85%) for narrowing, and 1% (95% CI 1 – 4%; I2 = 0%) for deformation. Device braid ovalization data were not available. Conclusion The findings of this study suggest that FD treatment for IAs generally exhibits low rates of fish‐mouthing, device braid narrowing, collapsing, and deformation. However, the lack of standardized definitions hinders the ability to objectively compare device outcomes, emphasizing the need for uniform device‐related complication definitions in future prospective studies on FD.

Details

Language :
English
ISSN :
26945746
Volume :
3
Issue :
S2
Database :
Directory of Open Access Journals
Journal :
Stroke: Vascular and Interventional Neurology
Publication Type :
Academic Journal
Accession number :
edsdoj.f5c3c8917d5444a0b1cd6461c23bca2b
Document Type :
article
Full Text :
https://doi.org/10.1161/SVIN.03.suppl_2.007