Back to Search Start Over

Analytical validation of quantitative SARS-CoV-2 subgenomic and viral load laboratory developed tests conducted on the Panther FusionĀ® (Hologic) with preliminary application to clinical samples.

Authors :
Ines Lakhal-Naouar
Holly R Hack
Edgar Moradel
Amie Jarra
Hannah L Grove
Rani M Ismael
Steven Padilla
Dante Coleman
Jason Ouellette
Janice Darden
Casey Storme
Kristina K Peachman
Tara L Hall
Mark E Huhtanen
Paul T Scott
Shilpa Hakre
Linda L Jagodzinski
Sheila A Peel
Source :
PLoS ONE, Vol 18, Iss 6, p e0287576 (2023)
Publication Year :
2023
Publisher :
Public Library of Science (PLoS), 2023.

Abstract

ObjectiveValidate the performance characteristics of two analyte specific, laboratory developed tests (LDTs) for the quantification of SARS-CoV-2 subgenomic RNA (sgRNA) and viral load on the Hologic Panther Fusion® using the Open Access functionality.MethodsCustom-designed primers/probe sets targeting the SARS-CoV-2 Envelope gene (E) and subgenomic E were optimized. A 20-day performance validation following laboratory developed test requirements was conducted to assess assay precision, accuracy, analytical sensitivity/specificity, lower limit of detection and reportable range.ResultsQuantitative SARS-CoV-2 sgRNA (LDT-Quant sgRNA) assay, which measures intermediates of replication, and viral load (LDT-Quant VLCoV) assay demonstrated acceptable performance. Both assays were linear with an R2 and slope equal to 0.99 and 1.00, respectively. Assay precision was evaluated between 4-6 Log10 with a maximum CV of 2.6% and 2.5% for LDT-Quant sgRNA and LDT-Quant VLCoV respectively. Using negative or positive SARS-CoV-2 human nasopharyngeal swab samples, both assays were accurate (kappa coefficient of 1.00 and 0.92). Common respiratory flora and other viral pathogens were not detected and did not interfere with the detection or quantification by either assay. Based on 95% detection, the assay LLODs were 729 and 1206 Copies/mL for the sgRNA and VL load LDTs, respectively.ConclusionThe LDT-Quant sgRNA and LDT-Quant VLCoV demonstrated good analytical performance. These assays could be further investigated as alternative monitoring assays for viral replication; and thus, medical management in clinical settings which could inform isolation/quarantine requirements.

Subjects

Subjects :
Medicine
Science

Details

Language :
English
ISSN :
19326203
Volume :
18
Issue :
6
Database :
Directory of Open Access Journals
Journal :
PLoS ONE
Publication Type :
Academic Journal
Accession number :
edsdoj.f9ca43cf817f44cab7a4ef6f4b313754
Document Type :
article
Full Text :
https://doi.org/10.1371/journal.pone.0287576