Back to Search Start Over

Decreasing inconsistent alarms notifications: a pragmatic clinical trial in a post-anesthesia care unit

Authors :
Saullo Queiroz Silveira
Rafael Sousa Fava Nersessian
Arthur de Campos Vieira Abib
Leonardo Barbosa Santos
Fernando Nardy Bellicieri
Karen Kato Botelho
Helidea de Oliveira Lima
Renata Mazzoni de Queiroz
Gabriel Silva dos Anjos
Hermann dos Santos Fernandes
Glenio B. Mizubuti
Joaquim Edson Vieira
Leopoldo Muniz da Silva
Source :
Brazilian Journal of Anesthesiology, Vol 74, Iss 3, Pp 744456- (2024)
Publication Year :
2024
Publisher :
Elsevier, 2024.

Abstract

Background: Alarms alert healthcare professionals of deviations from normal/physiologic status. However, alarm fatigue may occur when their high pitch and diversity overwhelm clinicians, possibly leading to alarms being disabled, paused, and/or ignored. We aimed to determine whether a staff educational program on customizing alarm settings of bedside monitors may decrease inconsistent alarms in the Post-Anesthesia Care Unit (PACU). Methods: This is a prospective, analytic, quantitative, pragmatic, open-label, single-arm study. The outcome was evaluated on PACU admission before (P1) and after (P2) the implementation of the educational program. The heart rate, blood pressure, and oxygen saturation alarms were selected for clinical consistency. Results: A total of 260 patients were included and 344 clinical alarms collected, with 270 (78.4%) before (P1), and 74 (21.6%) after (P2) the intervention. Among the 270 alarms in P1, 45.2% were inconsistent (i.e., false alarms), compared to 9.4% of the 74 in P2. Patients with consistent alarms occurred in 30% in the P1 and 27% in the P2 (p = 0.08). Patients with inconsistent alarms occurred in 25.4% in the P1 and in 3.8% in the P2. Ignored consistent alarms were reduced from 21.5% to 2.6% (p = 0.004) in the P2 group. The educational program was a protective factor for the inconsistent clinical alarm (OR = 0.11 [95% CI 0.04–0.3]; p < 0.001) after adjustments for age, gender, and ASA physical status. Conclusion: Customizing alarm settings on PACU admission proved to be a protective factor against inconsistent alarm notifications of multiparametric monitors.

Details

Language :
English
ISSN :
01040014
Volume :
74
Issue :
3
Database :
Directory of Open Access Journals
Journal :
Brazilian Journal of Anesthesiology
Publication Type :
Academic Journal
Accession number :
edsdoj.fc777a177a640c3966f16895e991401
Document Type :
article
Full Text :
https://doi.org/10.1016/j.bjane.2023.07.013