Back to Search Start Over

Noise performance of high-Tc DC SQUID magnetometers

Authors :
Fife, A.A.
Anderson, G.
Angus, V.
Backhouse, C.
Betts, K.
Burbank, M.B.
Cragg, R.A.
Ferguson, K.
Habib, F.
Kubik, P.R.
Nomura, J.
Smith, M.
Spear, P.
Westera, W.
Zhou, H.
Vrba, J.
Heinrich, B.
Curzon, A.E.
Irwin, J.C.
Chrzanowski, J.
Burany, X.M.
Govorkov, S.
Brown, P.
Xing, W.B.
Source :
IEEE Transactions on Applied Superconductivity. June, 1995, Vol. 5 Issue 2, p3113, 6 p.
Publication Year :
1995

Abstract

Noise performance of three types of high-transition-temperature direct current superconducting quantum interference device (DC SQUID) magnetometers fabricated from YBCO and STO films and operating at or near 77 K is investigated. Results indicate low frequency energy sensitivities in uncoupled SQUIDs and excess low-frequency noise in flip-chip coupled magnetometers.