Back to Search Start Over

Helmholtz resonance of pitot pressure measurements in impulsive hypersonic test facilities

Authors :
McGilvray, Matthew
Jacobs, Peter A.
Morgan, Richard G.
Gollan, Rowan J.
Jacobs, Carolyn M.
Source :
AIAA Journal. Oct, 2009, Vol. 47 Issue 10, p2430, 10 p.
Publication Year :
2009

Abstract

Experimental pitot pressure measurements in impulse facilities have typically had large-scale harmonic fluctuations associated with them. A combined experimental and numerical approach is used to investigate if a Helmholtz resonance is created from the shrouding that protects the pressure sensor from particle impact, rather than from disturbances being present in the freestream. To verify this experimentally, hydraulic oil was used to change the sound speed in the cavity. Numerical calculations of the pitot probe were used to show that both the steady and the expected transient inflow cause a Helmholtz resonance of similar period. However, a 5 % isothermal level of freestream noise was required to match the experimental fluctuation levels. Viscous effects were also shown to be significant during the initial transient response of the pressure measurement. A new pitot probe design was successfully tested and shown to be able to reduce the magnitude and period of the fluctuations. DOI: 10.2514/1.42543

Details

Language :
English
ISSN :
00011452
Volume :
47
Issue :
10
Database :
Gale General OneFile
Journal :
AIAA Journal
Publication Type :
Academic Journal
Accession number :
edsgcl.209900744