Back to Search Start Over

Performance Characteristics of Body Fuild Cytology: Analysis of 344 380 Responses From the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytopathology

Authors :
Tabatabai, Z. Laura
Nayar, Ritu
Souers, Rhona J.
Crothers, Barbara A.
Davey, Diane Davis
Source :
Archives of Pathology & Laboratory Medicine. January, 2018, Vol. 142 Issue 1, p53, 6 p.
Publication Year :
2018

Abstract

Context.--Body fluid cytology is an important diagnostic tool used to identify various conditions. However, an accurate diagnosis in this setting can sometimes be challenging.Objective.--To identify the performance characteristics of body fluid cytology by analyzing participant responses from the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytopathology.Design.--Participant responses from 5102 slides were analyzed for concordance to the general category (GC) and to the reference diagnosis (RD). Nonlinear mixed models were used to analyze concordance.Results.--The overall GC concordance was 95.2%. The GC type, participant type, and preparation type were significantly associated with GC concordance (P < .001). Concordance for malignant cases was higher than it was for benign cases. Cytotechnologists had better GC concordance compared to pathologists. ThinPrep (Hologic, Marlborough, Massachusetts) slides had the highest GC concordance. Participant type, fluid type, preparation type, and participant interpretation were significantly associated with rD concordance (P < .001). Pathologists performed better than cytotechnologists did for RD concordance. Pericardial fluid had the lowest RD concordance, especially for cases with normal or reactive findings. Modified Giemsa-stained slides performed best for lymphoma and hematopoietic malignancy. Small cell carcinoma had the highest GC concordance, and its RD concordance was higher in pleural than in peritoneal fluids. Adenocarcinoma showed the highest concordance rates for both GC and RD.Conclusions.--This study illustrates the challenges associated with interpreting body fluid cytology, particularly in pericardial fluid, and the factors that may affect accurate diagnoses. The results also highlight the value of using multiple preparation types in challenging cases.(Arch Pathol Lab Med. 2018;142:53-58; doi: 10.5858/arpa.2016-0509-CP)<br />Body fluid cytology is an important diagnostic test for various malignant and benign conditions. Effusions can be caused by inflammatory, infectious, and benign; neoplastic or malignant; and primary or metastatic [...]

Details

Language :
English
ISSN :
15432165
Volume :
142
Issue :
1
Database :
Gale General OneFile
Journal :
Archives of Pathology & Laboratory Medicine
Publication Type :
Academic Journal
Accession number :
edsgcl.533000139
Full Text :
https://doi.org/10.5858/arpa.2016-0509-CP