Back to Search
Start Over
STS-3/OSS-1 Plasma Diagnostics Package (PDP) measurements of Orbiter transmitter and subsystem electromagnetic interference
- Source :
- Systematics General Corp. The Shuttle Environ. Workshop.
- Publication Year :
- 1983
- Publisher :
- United States: NASA Center for Aerospace Information (CASI), 1983.
-
Abstract
- The plasma diagnostics package receiver system is described to identify the various antennas and to characterize the complement of receivers which cover the frequency range of 30 Hz to 800 Hz and S-band at 2200 + or - 300 MHz. Sample results are presented to show the variability of electromagnetic effects associated with the orbiter and the time variability of these effects. The electric field and magnetic field maximum and minimum field strength spectra observed during the mission at the pallet location are plotted. Values are also derived for the maximum UHF transmitter and S-band transmitter field strengths. Calibration data to convert from the survey plots to actual narrowband and broadband field strengths are listed.
- Subjects :
- Communications And Radar
Subjects
Details
- Language :
- English
- Database :
- NASA Technical Reports
- Journal :
- Systematics General Corp. The Shuttle Environ. Workshop
- Publication Type :
- Report
- Accession number :
- edsnas.19830014037
- Document Type :
- Report