Boston type I keratoprosthesis-donor cornea interface evaluated by high-definition spectral-domain anterior segment optical coherence tomography

Authors :
Fernandez,Ana G Alzaga
Radcliffe,Nathan M
Sippel,Kimberly C
Rosenblatt,Mark I
Sood,Priyanka
Starr,Christopher E
Ciralsky,Jessica B
D'Amico,Donald J
Kiss,Szilárd
Fernandez,Ana G Alzaga
Radcliffe,Nathan M
Sippel,Kimberly C
Rosenblatt,Mark I
Sood,Priyanka
Starr,Christopher E
Ciralsky,Jessica B
D'Amico,Donald J
Kiss,Szilárd
Publication Year :
2012

Abstract

Ana G Alzaga Fernandez,* Nathan M Radcliffe,* Kimberly C Sippel, Mark I Rosenblatt, Priyanka Sood, Christopher E Starr, Jessica B Ciralsky, Donald J D'Amico, Szilárd KissDepartment of Ophthalmology, Weill Cornell Medical College, New York-Presbyterian Hospital, New York, NY, USA*These authors contributed equally to this work and both are considered principal authorsBackground: The purpose of this study was to assess whether the resolution offered by two different, recently commercially available high-resolution, spectral-domain anterior segment optical coherence tomography (AS-OCT) instruments allows for detailed anatomic characterization of the critical device-donor cornea interface in eyes implanted with the Boston type I permanent keratoprosthesis.Methods: Eighteen eyes of 17 patients implanted with the Boston type I keratoprosthesis were included in this retrospective case series. All eyes were quantitatively evaluated using the Cirrus HD-OCT while a subset (five eyes) was also qualitatively imaged using the Spectralis Anterior Segment Module. Images from these instruments were analyzed for evidence of epithelial migration onto the anterior surface of the keratoprosthesis front plate, and presence of a vertical gap between the posterior surface of the front plate and the underlying carrier donor corneal tissue. Quantitative data was obtained utilizing the caliper function on the Cirrus HD-OCT.Results: The mean duration between AS-OCT imaging and keratoprosthesis placement was 29 months. As assessed by the Cirrus HD-OCT, 83% of eyes exhibited epithelial migration over the edge of the front plate. Fifty-six percent of the keratoprosthesis devices displayed good apposition of the device with the carrier corneal donor tissue. When a vertical gap was present (44% of eyes), the mean gap was 40 (range 8–104) microns. The Spectralis Anterior Segment Module also displayed sufficient resolution to allow for similar characterization of the devi

Details

Database :
OAIster
Notes :
text/html, English
Publication Type :
Electronic Resource
Accession number :
edsoai.ocn808836905
Document Type :
Electronic Resource