Back to Search Start Over

Comparison of Different Matrices as Potential Quality Control Samples for Neurochemical Dementia Diagnostics

Authors :
Lelental, Natalia
Brandner, Sebastian
Kofanova, Olga
Blennow, Kaj
Zetterberg, Henrikd
Andreasson, Ulf
Engelborghs, Sebastiaan
Mroczko, Barbara
Gabryelewicz, Tomasz
Teunissen, Charlotte
Mollenhauer, Brit
Parnetti, Lucilla
Chiasserini, Davide
Molinuevo, Jose Lui
Perret Liaudet, Armand
Verbeek, Marcel M
Andreasen, Niel
Brosseron, Frederic
Bahl, Justyna M. C
Herukka, Sanna Kaisa
Hausner, Lucrezia
Frölich, Lutz
Labonte, Anne
Poirier, Jude
Miller, Anne Marie
Zilka, Norbert
Kovacech, Branislav
Urbani, Andrea
Suardi, Silvia
Oliveira, Catarina
Baldeiras, Ine
Dubois, Bruno
Rot, Uro
Lehmann, Sylvain
Skinningsrud, Ander
Betsou, Fay
Wiltfang, Jen
Gkatzima, Olymbia
Winblad, Bengt
Buchfelder, Michael
Kornhuber, Johanne
Lewczuk, Piotr
Urbani, Andrea (ORCID:0000-0001-9168-3174)
Lelental, Natalia
Brandner, Sebastian
Kofanova, Olga
Blennow, Kaj
Zetterberg, Henrikd
Andreasson, Ulf
Engelborghs, Sebastiaan
Mroczko, Barbara
Gabryelewicz, Tomasz
Teunissen, Charlotte
Mollenhauer, Brit
Parnetti, Lucilla
Chiasserini, Davide
Molinuevo, Jose Lui
Perret Liaudet, Armand
Verbeek, Marcel M
Andreasen, Niel
Brosseron, Frederic
Bahl, Justyna M. C
Herukka, Sanna Kaisa
Hausner, Lucrezia
Frölich, Lutz
Labonte, Anne
Poirier, Jude
Miller, Anne Marie
Zilka, Norbert
Kovacech, Branislav
Urbani, Andrea
Suardi, Silvia
Oliveira, Catarina
Baldeiras, Ine
Dubois, Bruno
Rot, Uro
Lehmann, Sylvain
Skinningsrud, Ander
Betsou, Fay
Wiltfang, Jen
Gkatzima, Olymbia
Winblad, Bengt
Buchfelder, Michael
Kornhuber, Johanne
Lewczuk, Piotr
Urbani, Andrea (ORCID:0000-0001-9168-3174)
Publication Year :
2016

Abstract

Aim. Lactulose/mannitol ratio is used to assess intestinal barrier function. Aim of this work was to develop a robust and rapid method for the analysis of lactulose and mannitol in urine by liquid chromatography coupled to tandem mass spectrometry. Lactulose/mannitol ratio has been measured in pediatric patients suffering from irritable bowel syndrome. Methods. Calibration curves and raffinose, used as internal standard, were prepared in water : acetonitrile 20:80. Fifty mu L of urine sample was added to 450 mu L of internal standard solution. The chromatographic separation was performed using a Luna NH2 column operating at a flow rate of 200 mu L/min and eluted with a linear gradient from 20% to 80% water in acetonitrile. Total run time is 9 minutes. The mass spectrometry operates in electrospray negative mode. Method was fully validated according to European Medicine Agency guidelines. Results and Conclusions. Linearity ranged from 10 to 1000 mg/L for mannitol and 2.5 to 1000 mg/L for lactulose. Imprecision in intra-and interassay was lower than 15% for both analytes. Accuracy was higher than 85%. Lactulose/mannitol ratio in pediatric patients is significantly higher than that measured in controls. The presented method, rapid and sensitive, is suitable in a clinical laboratory.

Details

Database :
OAIster
Notes :
English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1105029040
Document Type :
Electronic Resource