The Multi-center Evaluation of the Accuracy of the Contrast MEdium INduced Pd/Pa RaTiO in Predicting FFR (MEMENTOFFR) Study

Authors :
Leone, Antonio Maria
Martin Reyes, Roberto
Baptista, Sergio B.
Amabile, Nicola
Raposo, Lui
Franco Pelaez, Juan Antonio
Trani, Carlo
Cialdella, Pio
Basile, Eloisa
Zimbardo, Giuseppe
Burzotta, Francesco
Porto, Italo
Aurigemma, Cristina
Rebuzzi, Antonio Giuseppe
Faustino, Mariana
Niccoli, Giampaolo
Abreu, Pedro F.
Slama, Michel S.
Spagnoli, Vincent
Arrieta, Miren Telleria
Amat Santos, Ignacio J.
De La Torre Hernandez, Jose M.
Palop, Ramon Lopez
Crea, Filippo
Leone, Antonio Maria (ORCID:0000-0002-1276-9883)
Trani, Carlo (ORCID:0000-0001-9777-013X)
Burzotta, Francesco (ORCID:0000-0002-6569-9401)
Porto, Italo (ORCID:0000-0002-9854-5046)
Rebuzzi, Antonio Giuseppe (ORCID:0000-0002-9873-957X)
Niccoli, Giampaolo (ORCID:0000-0002-3187-6262)
Crea, Filippo (ORCID:0000-0001-9404-8846)
Leone, Antonio Maria
Martin Reyes, Roberto
Baptista, Sergio B.
Amabile, Nicola
Raposo, Lui
Franco Pelaez, Juan Antonio
Trani, Carlo
Cialdella, Pio
Basile, Eloisa
Zimbardo, Giuseppe
Burzotta, Francesco
Porto, Italo
Aurigemma, Cristina
Rebuzzi, Antonio Giuseppe
Faustino, Mariana
Niccoli, Giampaolo
Abreu, Pedro F.
Slama, Michel S.
Spagnoli, Vincent
Arrieta, Miren Telleria
Amat Santos, Ignacio J.
De La Torre Hernandez, Jose M.
Palop, Ramon Lopez
Crea, Filippo
Leone, Antonio Maria (ORCID:0000-0002-1276-9883)
Trani, Carlo (ORCID:0000-0001-9777-013X)
Burzotta, Francesco (ORCID:0000-0002-6569-9401)
Porto, Italo (ORCID:0000-0002-9854-5046)
Rebuzzi, Antonio Giuseppe (ORCID:0000-0002-9873-957X)
Niccoli, Giampaolo (ORCID:0000-0002-3187-6262)
Crea, Filippo (ORCID:0000-0001-9404-8846)
Publication Year :
2016

Abstract

Aims: Adenosine administration is needed for the achievement of maximal hyperaemia fractional flow reserve (FFR) assessment. The objective was to test the accuracy of Pd/Pa ratio registered during submaximal hyperaemia induced by non-ionic contrast medium (contrast FFR [cFFR]) in predicting FFR and comparing it to the performance of resting Pd/Pa in a collaborative registry of 926 patients enrolled in 10 hospitals from four European countries (Italy, Spain, France and Portugal). Methods and results: Resting Pd/Pa, cFFR and FFR were measured in 1,026 coronary stenoses functionally evaluated using commercially available pressure wires. cFFR was obtained after intracoronary injection of contrast medium, while FFR was measured after administration of adenosine. Resting Pd/Pa and cFFR were significantly higher than FFR (0.93±0.05 vs. 0.87±0.08 vs. 0.84±0.08, p<0.001). A strong correlation and a close agreement at Bland-Altman analysis between cFFR and FFR were observed (r=0.90, p<0.001 and 95% CI of disagreement: from-0.042 to 0.11). ROC curve analysis showed an excellent accuracy (89%) of the cFFR cut-off of ?0.85 in predicting an FFR value ?0.80 (AUC 0.95 [95% CI: 0.94-0.96]), significantly better than that observed using resting Pd/Pa (AUC: 0.90, 95% CI: 0.88-0.91; p<0.001). A cFFR/ FFR hybrid approach showed a significantly lower number of lesions requiring adenosine than a resting Pd/ Pa/FFR hybrid approach (22% vs. 44%, p<0.0001). Conclusions: cFFR is accurate in predicting the functional significance of coronary stenosis. This could allow limiting the use of adenosine to obtain FFR to a minority of stenoses with considerable savings of time and costs.