Back to Search Start Over

Ultra-high field MR angiography in human migraine models: a 3.0T/7.0T comparison study

Authors :
Christensen, Casper Emil
Younis, Samaira
Lindberg, Ulrich
Boer, Vincent Oltman
de Koning, Patrick
Petersen, Esben Thade
Paulson, Olaf Bjarne
Larsson, Henrik Bo Wiberg
Amin, Faisal Mohammad
Ashina, Messoud
Christensen, Casper Emil
Younis, Samaira
Lindberg, Ulrich
Boer, Vincent Oltman
de Koning, Patrick
Petersen, Esben Thade
Paulson, Olaf Bjarne
Larsson, Henrik Bo Wiberg
Amin, Faisal Mohammad
Ashina, Messoud
Source :
Christensen , C E , Younis , S , Lindberg , U , Boer , V O , de Koning , P , Petersen , E T , Paulson , O B , Larsson , H B W , Amin , F M & Ashina , M 2019 , ' Ultra-high field MR angiography in human migraine models: a 3.0T/7.0T comparison study ' , The Journal of Headache and Pain , vol. 20 , no. 1 , 48 .
Publication Year :
2019

Abstract

Background: Sildenafil and calcitonin gene-related peptide both dilate the intradural segments of the middle meningeal artery measured with 3.0 tesla (T) MR angiography. Here we hypothesized that an increase in field strength to 7.0T and concomitant enhanced voxel resolution would lower variance in measurements of dilation in the intradural middle meningeal artery. Methods: Five subjects completed two sessions at respectively 3.0T and 7.0T. Each session comprised MR angiography scans once before and twice after administration of sildenafil, calcitonin gene-related peptide or placebo in a three-way, crossover, double-blind, placebo-controlled design. Results: Standard deviations of arterial circumference revealed no difference between 3.0T and 7.0T measurements (p=0.379). We found a decrease in standard deviation from our original angiography analysis software (QMra) to a newer (LAVA) software package (p= 0.379). We found a decrease in standard deviation from our original angiography analysissoftware (QMra) to a newer (LAVA) software package (p < 0.001). Furthermore, we found that the dilation aftersildenafil and calcitonin gene-related peptide were comparable between 3.0 T and 7.0 T. Conclusions: Our findings suggest no gain from the increase in voxel resolution but cemented dilatory findingsfrom earlier. The implemented software update improved variance in circumference measurements in the intraduralmiddle meningeal artery, which should be exploited in future studies.

Details

Database :
OAIster
Journal :
Christensen , C E , Younis , S , Lindberg , U , Boer , V O , de Koning , P , Petersen , E T , Paulson , O B , Larsson , H B W , Amin , F M & Ashina , M 2019 , ' Ultra-high field MR angiography in human migraine models: a 3.0T/7.0T comparison study ' , The Journal of Headache and Pain , vol. 20 , no. 1 , 48 .
Notes :
application/pdf, English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1110502199
Document Type :
Electronic Resource