Back to Search Start Over

Diagnostic performance of smear microscopy and incremental yield of Xpert in detection of pulmonary tuberculosis in Rwanda

Authors :
UCL - SSS/IREC/MBLG - Pôle de Microbiologie médicale
UCL - (SLuc) Service de microbiologie
Ngabonziza, Jean Claude Semuto
Ssengooba, Willy
Mutua, Florence
Torrea, Gabriela
Dushime, Augustin
Gasana, Michel
André, Emmanuel
Uwamungu, Schifra
Nyaruhirira, Alaine Umubyeyi
Mwaengo, Dufton
Muvunyi, Claude Mambo
UCL - SSS/IREC/MBLG - Pôle de Microbiologie médicale
UCL - (SLuc) Service de microbiologie
Ngabonziza, Jean Claude Semuto
Ssengooba, Willy
Mutua, Florence
Torrea, Gabriela
Dushime, Augustin
Gasana, Michel
André, Emmanuel
Uwamungu, Schifra
Nyaruhirira, Alaine Umubyeyi
Mwaengo, Dufton
Muvunyi, Claude Mambo
Source :
BMC Infectious Diseases, Vol. 16, no. 1, p. 660 [1-7] (2016)
Publication Year :
2016

Abstract

Background Tuberculosis control program of Rwanda is currently phasing in light emitting diode-fluorescent microscopy (LED-FM) as an alternative to Ziehl-Neelsen (ZN) smear microscopy. This, alongside the newly introduced Xpert (Cepheid, Sunnyvale, CA, USA) is expected to improve diagnosis of tuberculosis and detection of rifampicin resistance in patients at health facilities. We assessed the accuracy of smear microscopy and the incremental sensitivity of Xpert at tuberculosis laboratories in Rwanda. Methods This was a cross-sectional study involving four laboratories performing ZN and four laboratories performing LED-FM microscopy. The laboratories include four intermediate (ILs) and four peripheral (PLs) laboratories. After smear microscopy, the left-over of samples, of a single early-morning sputum from 648 participants, were tested using Xpert and mycobacterial culture as a reference standard. Sensitivity of each test was compared and the incremental sensitivity of Xpert after a negative smear was assessed. Results A total of 96 presumptive pulmonary tuberculosis participants were culture positive for M. tuberculosis. The overall sensitivity in PL of ZN was 55.1 % (40.2–69.3 %), LED-FM was 37 % (19.4–57.6 %) and Xpert was 77.6 % (66.6–86.4 %) whereas in ILs the same value for ZN was 58.3 % (27.7–84.8 %), LED-FM was 62.5 % (24.5–91.5 %) and Xpert was 90 (68.3–98.8 %). The sensitivity for all tests was significantly higher among HIV-negative individuals (all test p <0.05). The overall incremental sensitivity of Xpert over smear microscopy was 32.3 %; p < 0.0001. The incremental sensitivity of Xpert was statistically significant for both smear methods at PL (32.9 %; p = 0.001) but not at the ILs (30 %; p = 0.125) for both smear methods. Conclusions Our study findings of the early implementation of the LED-FM did not reveal significant increment in sensitivity compared to the method being phased out (ZN). This study showed a significant incremental sensitivity for X

Details

Database :
OAIster
Journal :
BMC Infectious Diseases, Vol. 16, no. 1, p. 660 [1-7] (2016)
Notes :
English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1130466713
Document Type :
Electronic Resource