Back to Search Start Over

Extubation from high-frequency oscillatory ventilation in extremely low birth weight infants: A prospective observational study

Authors :
Tana, M.
Lio, A.
Tirone, C.
Aurilia, C.
Tiberi, Eloisa
Serrao, F.
Purcaro, Velia
Corsello, M.
Catenazzi, P.
D'Andrea, Vito
Barone, G.
Ricci, C.
Pastorino, Roberta
Vento, Giovanni
Tiberi E.
Purcaro V.
D'Andrea V. (ORCID:0000-0002-0980-799X)
Pastorino R. (ORCID:0000-0001-5013-0733)
Vento G. (ORCID:0000-0002-8132-5127)
Tana, M.
Lio, A.
Tirone, C.
Aurilia, C.
Tiberi, Eloisa
Serrao, F.
Purcaro, Velia
Corsello, M.
Catenazzi, P.
D'Andrea, Vito
Barone, G.
Ricci, C.
Pastorino, Roberta
Vento, Giovanni
Tiberi E.
Purcaro V.
D'Andrea V. (ORCID:0000-0002-0980-799X)
Pastorino R. (ORCID:0000-0001-5013-0733)
Vento G. (ORCID:0000-0002-8132-5127)
Publication Year :
2018

Abstract

Objective To evaluate if weaning from high-frequency oscillatory ventilation (HFOV) directly to a non-invasive mode of respiratory support is feasible and results in successful extubation in extremely low birth weight (ELBW) infants. Design Prospective observational study. Setting Tertiary neonatal intensive care unit. Patients One hundred and eight ELBW infants of 26.2±1.4 weeks of gestational age (GA) directly extubated from HFOV. Interventions All infants were managed with elective HFOV and received surfactant after a recruitment HFOV manoeuvre. Extubation was attempted at mean airways pressure (MAP) ≤6 cm H 2 O with FiO 2 ≤0.25. After extubation, all infants were supported by nasal continuous positive airway pressure (6-8 cm H 2 O). Main outcome measures Extubation failure (clinical deterioration requiring reintubation) was defined as shorter than 7 days. Results Ninety patients (83%) were successfully extubated and 18 (17%) required reintubation. No significant differences were found between the two groups in terms of birth weight, day of life and weight at the time of extubation. Multivariable analysis showed that GA (OR 1.71; 95% CI 1.04, 2.08) and higher MAP prior to surfactant (OR 1.51; 95% CI 1.06, 2.15) were associated with successful extubation. Conclusions In ELBW infants, direct extubation from HFOV at MAP ≤6 cm H 2 O with FiO 2 ≤0.25 is feasible. Our extubation success rate (83%) is higher than conventional mechanical ventilation in this very vulnerable class of infants.

Details

Database :
OAIster
Notes :
English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1145018423
Document Type :
Electronic Resource