Back to Search
Start Over
A new technique for reconstruction of the atrophied narrow alveolar crest in the maxilla using morselized impacted bone allograft and later placement of dental implants
- Publication Year :
- 2008
-
Abstract
- Background: In cases when the alveolar crest is too narrow to host an implant, lateral augmentation is required. The use of autogenous bone blocks harvested from the iliac crest is often demanded. One disadvantage is the associated patient morbidity. Purpose: The purpose of this study was to clinically and histologically evaluate the use of morselized impacted bone allograft, a novel technique for reconstruction of the narrow alveolar crest. Materials and methods: Two patients with completely edentulous maxillae and one partially edentulous, with a mean age of 77 years (range 76-79 years) were included in the study. The alveolar crest width was < 3 mm without possibility to place any implant. Bone grafts were taken from a bone bank in Gavle Hospital. Bone from the neck of femur heads was milled to produce bone chips. The milled bone was partially defatted by rinsing in 37 degrees C saline solution. After compression of the graft pieces with a size of 15 mm (height), 30 mm (length), and 6 mm (width), they were then fit to adapt to the buccal surface of the atrophied alveolar crest. One piece was placed to the right and one to the left side of the midline. On both sides fibrin glue was used (Tisseel (R), Baxter AG, Vienna, Austria) to stabilize the graft. After 6 months of graft healing, dental implants were placed, simultaneously biopsies were harvested and in one patient two oxidized microimplants were placed. At the time of abutment connection, microimplants were retrieved with surrounding bone for histology. Fixed screw-retained bridges were fabricated in mean of 7 months after implant surgery. Radiographs were taken before and after implant surgery and after 1 year of loading. Results: Sixteen implants with an oxidized surface were placed (TiUnite (R), Nobel Biocare AB, Goteborg, Sweden). After 1 year of functional loading, all implants were clinically stable. The marginal bone loss was 1.4 mm (SD 0.3) after 1 year of loading. The histological examination show
Details
- Database :
- OAIster
- Notes :
- English
- Publication Type :
- Electronic Resource
- Accession number :
- edsoai.on1233589769
- Document Type :
- Electronic Resource
- Full Text :
- https://doi.org/10.1111.j.1708-8208.2007.00063.x