A Highly Sensitive Nonextraction-Assisted HPLC Method with Fluorescence Detection for Quantification of Duvelisib in Plasma Samples and its Application to Pharmacokinetic Study in Rats

Authors :
Sayed,Ahmed Y
Khalil,Nasr Y
Almomen,Aliyah
Alzoman,Nourah Z
Almehizia,Abdulrahman A
Darwish,Ibrahim A
Sayed,Ahmed Y
Khalil,Nasr Y
Almomen,Aliyah
Alzoman,Nourah Z
Almehizia,Abdulrahman A
Darwish,Ibrahim A
Publication Year :
2021

Abstract

Ahmed Y Sayed, Nasr Y Khalil, Aliyah Almomen, Nourah Z Alzoman, Abdulrahman A Almehizia, Ibrahim A Darwish Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, Riyadh, 11451, Saudi ArabiaCorrespondence: Ibrahim A DarwishDepartment of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh, 11451, Saudi ArabiaTel +966-114677348Fax +966-114676220Email idarwish@ksu.edu.saBackground: Duvelisib (DUV) is a new oral phosphoinositide-3-kinase (PI3K)-δ and PI3K-γ inhibitor. It has been recently granted an accelerated approval for treatment of adult patients with relapsed or refractory chronic lymphocytic leukemia (CLL) and small lymphocytic lymphoma (SLL). It is also effective in therapy of T-cell lymphoma, solid tumors, and non-Hodgkin’s lymphoma. In literature, there is no method valid for quantitation of DUV in human plasma for its therapeutic monitoring and pharmacokinetic studies.Purpose: The purpose of this study is the establishment of a highly sensitive HPLC method with fluorescence detection for quantitation of DUV in plasma for its therapeutic monitoring and pharmacokinetic studies of DUV.Methods: The resolution of DUV and the internal standard (IS) olaparib (OLA) was achieved on Nucleosil CN column, with a mobile phase composed of acetonitrile:water (25:75, v/v) at a flow rate of 1.7 mL min– 1. The fluorescence of both DUV and OLA was detected at 410 nm after excitation at 280 nm. The method was validated according to the guidelines of bioanalytical method validation.Results: The method was linear in the range of 5– 100 ng mL– 1, and its limit of detection (LOD) and limit of quantitation (LOQ) were 2.12 ng mL– 1 and 7 ng mL– 1, respectively. The precisions of the method were ≤ 8.26%, and its accuracies were ≥ 95.32%. All the other validation parameters were satisfactory. The proposed method was successfully

Details

Database :
OAIster
Notes :
text/html, English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1265081845
Document Type :
Electronic Resource