Back to Search Start Over

Comparative analysis of targeted next-generation sequencing panels for the detection of gene mutations in chronic lymphocytic leukemia : an ERIC multi-center study

Authors :
Sutton, Lesley-Ann
Ljungström, Viktor
Enjuanes, Anna
Cortese, Diego
Skaftason, Aron
Tausch, Eugen
Kozubik, Katerina Stano
Nadeu, Ferran
Armand, Marine
Malcikova, Jikta
Djureinovic, Tatjana
Forster, Jade
Davis, Zadie
Oscier, David
Rossi, Davide
Ghia, Paolo
Strefford, Jonathan C.
Pospisilova, Sarka
Stilgenbauer, Stephan
Davi, Frederic
Campo, Elias
Stamatopoulos, Kostas
Rosenquist, Richard
Sutton, Lesley-Ann
Ljungström, Viktor
Enjuanes, Anna
Cortese, Diego
Skaftason, Aron
Tausch, Eugen
Kozubik, Katerina Stano
Nadeu, Ferran
Armand, Marine
Malcikova, Jikta
Djureinovic, Tatjana
Forster, Jade
Davis, Zadie
Oscier, David
Rossi, Davide
Ghia, Paolo
Strefford, Jonathan C.
Pospisilova, Sarka
Stilgenbauer, Stephan
Davi, Frederic
Campo, Elias
Stamatopoulos, Kostas
Rosenquist, Richard
Publication Year :
2021

Abstract

Next-generation sequencing (NGS) has transitioned from research to clinical routine, yet the comparability of different technologies for mutation profiling remains an open question. We performed a European multicenter (n=6) evaluation of three amplicon-based NGS assays targeting 11 genes recurrently mutated in chronic lymphocytic leukemia. Each assay was assessed by two centers using 48 pre-characterized chronic lymphocytic leukemia samples; libraries were sequenced on the Illumina MiSeq instrument and bioinformatics analyses were centralized. Across all centers the median percentage of target reads >= 100x ranged from 94.299.8%. In order to rule out assay-specific technical variability, we first assessed variant calling at the individual assay level i.e., pairwise analysis of variants detected amongst partner centers. After filtering for variants present in the paired normal sample and removal of PCR/sequencing artefacts, the panels achieved 96.2% (Multiplicom), 97.7% (TruSeq) and 90% (HaloPlex) concordance at a variant allele frequency (VAF) 5%). We sought to investigate low-frequency mutations further by using a high-sensitivity assay containing unique molecular identifiers, which confirmed the presence of several minor subclonal mutations. Thus, while amplicon-based approaches can be adopted for somatic mutation detection with VAF 5%, after rigorous validation, the use of unique molecular identifiers may be necessary to reach a higher sensitivity and ensure consistent and accurate detection of low-frequency variants.

Details

Database :
OAIster
Notes :
application/pdf, English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1280659834
Document Type :
Electronic Resource
Full Text :
https://doi.org/10.3324.haematol.2019.234716