Back to Search Start Over

Impact of dynamic computed tomographic angiography on endograft sizing for endovascular aneurysm repair.

Authors :
Pol, J.A.
Truijers, M.
Vliet, J.A. van der
Fillinger, M.F.
Marra, S.P.
Renema, W.K.J.
Oostveen, L.J.
Schultze Kool, L.J.
Blankensteijn, J.D.
Pol, J.A.
Truijers, M.
Vliet, J.A. van der
Fillinger, M.F.
Marra, S.P.
Renema, W.K.J.
Oostveen, L.J.
Schultze Kool, L.J.
Blankensteijn, J.D.
Source :
Journal of Endovascular Therapy; 546; 51; 1526-6028; 5; 16; ~Journal of Endovascular Therapy~546~51~~~1526-6028~5~16~~
Publication Year :
2009

Abstract

Contains fulltext : 80349.pdf (publisher's version ) (Open Access)<br />PURPOSE: To quantify dynamic changes in aortoiliac dimensions using dynamic electrocardiographically (ECG)-gated computed tomographic angiography (CTA) and to investigate any potential impact on preoperative endograft sizing in relation to observer variability. METHODS: Dynamic ECG-gated CTA was performed in 18 patients with abdominal aortic aneurysms. Postprocessing resulted in 11 datasets per patient: 1 static CTA and 10 dynamic CTA series. Vessel diameter, length, and angulation were measured for all phases of the cardiac cycle. The differences between diastolic and systolic aneurysm dimensions were analyzed for significance using paired t tests. To assess intraobserver variability, 20 randomly selected datasets were analyzed twice. Intraobserver repeatability coefficients (RC) were calculated using Bland-Altman analysis. RESULTS: Mean aortic diameter at the proximal neck was 21.4+/-3.0 mm at diastole and 23.2+/-2.9 mm at systole, a mean increase of 1.8+/-0.4 mm (8.5%, p<0.01). The RC for the aortic diameter at the level of the proximal aneurysm neck was 1.9 mm (8.9%). At the distal sealing zones, the mean increase in diameter was 1.7+/-0.3 mm (14.1%, p<0.01) for the right and 1.8+/-0.5 mm (14.2%, p<0.01) for the left common iliac artery (CIA). At both distal sealing zones, the mean increase in CIA diameter exceeded the RC (10.0% for the right CIA and 12.6% for the left CIA). CONCLUSION: The observed changes in aneurysm dimension during the cardiac cycle are small and in the range of intraobserver variability, so dynamic changes in proximal aneurysm neck diameter and aneurysm length likely have little impact on preoperative endograft selection. However, changes in diameter at the distal sealing zones may be relevant to sizing, so distal oversizing of up to 20% should be considered to prevent distal type I endoleak.

Details

Database :
OAIster
Journal :
Journal of Endovascular Therapy; 546; 51; 1526-6028; 5; 16; ~Journal of Endovascular Therapy~546~51~~~1526-6028~5~16~~
Publication Type :
Electronic Resource
Accession number :
edsoai.on1284008346
Document Type :