Back to Search
Start Over
The effect of changing excitation frequency on parallel conductance in different sized hearts
- Source :
- White , P A , Brookes , C I , Ravn , H B , Stenbøg , E E , Christensen , T D , Chaturvedi , R R , Sorensen , K , Hjortdal , V E & Redington , A N 1998 , ' The effect of changing excitation frequency on parallel conductance in different sized hearts ' , Cardiovascular Research , vol. 38 , no. 3 , pp. 668-75 .
- Publication Year :
- 1998
-
Abstract
- OBJECTIVE: An important component of the ventricular volume measured using the conductance catheter technique is due to parallel conductance (Vc), which results from the extension of the electric field beyond the ventricular blood pool. Parallel conductance volume is normally estimated using the saline dilution method (Vc(saline dilution)), in which the conductivity of blood in the ventricle is transiently increased by injection of hypertonic saline. A simpler alternative has been reported by Gawne et al. [12]. Vc(dual frequency) is estimated from the difference in total conductance measured at two exciting frequencies and the method is based on the assumption that parallel conductance is mainly capacitive and hence is negligible at low frequency. The objective of this study was to determine whether the dual frequency technique could be used to substitute the saline dilution method to estimate Vc in different sized hearts.METHODS: The accuracy and linearity of a custom-built conductance catheter (CC) system was initially assessed in vitro. Subsequently, a CC and micromanometer were inserted into the left ventricle of seven 5 kg pigs (group 1) and six 50 kg pigs (group 2). Cardiac output was determined using thermodilution (group 1) and an ultrasonic flow probe (group 2) from which the slope coefficient (alpha) was determined. Steady state measurements and Vc estimated using saline dilution were performed at frequencies in the range of 5-40 kHz. All measurements were made at end-expiration. Finally, Vc was estimated from the change in end-systolic conductance between 5 kHz and 40 kHz using the dual frequency technique of Gawne et al. [12].RESULTS: There was no change in measured volume of a simple insulated cylindrical model when the stimulating frequency was varied from 5-40 kHz. Vc(saline dilution) varied significantly with frequency in group 1 (8.63 +/- 2.74 ml at 5 kHz; 11.51 +/- 2.65 ml at 40 kHz) (p = 0.01). Similar results were obtained in gro
Details
- Database :
- OAIster
- Journal :
- White , P A , Brookes , C I , Ravn , H B , Stenbøg , E E , Christensen , T D , Chaturvedi , R R , Sorensen , K , Hjortdal , V E & Redington , A N 1998 , ' The effect of changing excitation frequency on parallel conductance in different sized hearts ' , Cardiovascular Research , vol. 38 , no. 3 , pp. 668-75 .
- Notes :
- English
- Publication Type :
- Electronic Resource
- Accession number :
- edsoai.on1313489046
- Document Type :
- Electronic Resource