Back to Search
Start Over
International study on inter-reader variability for circulating tumor cells in breast cancer
- Source :
- Ignatiadis , M , Riethdorf , S , Bidard , FC , Vaucher , I , Khazour , M , Roth , F , Metallo , J , Rouas , G , Payne , RE , Coombes , RC , Teufel , I , Andergassen , U , Apostolaki , S , Politaki , E , Mavroudis , D , Bessi , S , Pestrin , M , De Leo , A , Campion , M , Reinholz , M , Perez , E , Piccart , M , Borgen , E , Naume , B , Jimenez , J , Aura , CM , Zorzino , L , Cassatella , MC , Sandri , MT , Mostert , B , Sleijfer , S , Kraan , J , Janni , W , Fehm , T , Rack , B , Terstappen , L , Repollet , M , Pierga , JY , Miller , C , Sotiriou , C , Michiels , S & Pantel , K 2014 , ' International study on inter-reader variability for circulating tumor cells in breast cancer ' , Breast Cancer Research , vol. 16 , no. 2 .
- Publication Year :
- 2014
-
Abstract
- Introduction: Circulating tumor cells (CTCs) have been studied in breast cancer with the CellSearch (R) system. Given the low CTC counts in non-metastatic breast cancer, it is important to evaluate the inter-reader agreement. Methods: CellSearch (R) images (N = 272) of either CTCs or white blood cells or artifacts from 109 non-metastatic (M0) and 22 metastatic (M1) breast cancer patients from reported studies were sent to 22 readers from 15 academic laboratories and 8 readers from two Veridex laboratories. Each image was scored as No CTC vs CTC HER2-vs CTC HER2+. The 8 Veridex readers were summarized to a Veridex Consensus (VC) to compare each academic reader using % agreement and kappa (.) statistics. Agreement was compared according to disease stage and CTC counts using the Wilcoxon signed rank test. Results: For CTC definition (No CTC vs CTC), the median agreement between academic readers and VC was 92% (range 69 to 97%) with a median. of 0.83 (range 0.37 to 0.93). Lower agreement was observed in images from M0 (median 91%, range 70 to 96%) compared to M1 (median 98%, range 64 to 100%) patients (P < 0.001) and from M0 and < 3CTCs (median 87%, range 66 to 95%) compared to M0 and >= 3CTCs samples (median 95%, range 77 to 99%), (P < 0.001). For CTC HER2 expression (HER2-vs HER2+), the median agreement was 87% (range 51 to 95%) with a median. of 0.74 (range 0.25 to 0.90). Conclusions: The inter-reader agreement for CTC definition was high. Reduced agreement was observed in M0 patients with low CTC counts. Continuous training and independent image review are required.
Details
- Database :
- OAIster
- Journal :
- Ignatiadis , M , Riethdorf , S , Bidard , FC , Vaucher , I , Khazour , M , Roth , F , Metallo , J , Rouas , G , Payne , RE , Coombes , RC , Teufel , I , Andergassen , U , Apostolaki , S , Politaki , E , Mavroudis , D , Bessi , S , Pestrin , M , De Leo , A , Campion , M , Reinholz , M , Perez , E , Piccart , M , Borgen , E , Naume , B , Jimenez , J , Aura , CM , Zorzino , L , Cassatella , MC , Sandri , MT , Mostert , B , Sleijfer , S , Kraan , J , Janni , W , Fehm , T , Rack , B , Terstappen , L , Repollet , M , Pierga , JY , Miller , C , Sotiriou , C , Michiels , S & Pantel , K 2014 , ' International study on inter-reader variability for circulating tumor cells in breast cancer ' , Breast Cancer Research , vol. 16 , no. 2 .
- Notes :
- application/pdf, und
- Publication Type :
- Electronic Resource
- Accession number :
- edsoai.on1313617794
- Document Type :
- Electronic Resource