Back to Search Start Over

Criterion validity of ultrasound in the identification of calcium pyrophosphate crystal deposits at the knee:an OMERACT ultrasound study

Authors :
Filippou, Georgios
Scanu, Anna
Adinolfi, Antonella
Toscano, Carmela
Gambera, Dario
Largo, Raquel
Naredo, Esperanza
Calvo, Emilio
Herrero-Beaumont, Gabriel
Zufferey, Pascal
Bonjour, Christel Madelaine
Maccarter, Daryl K.
Makman, Stanley
Weber, Zachary
Figus, Fabiana
Möller, Ingrid
Gutierrez, Marwin
Pineda, Carlos
Clavijo Cornejo, Denise
Garcia, Hector
Ilizaliturri, Victor
Mendoza Torres, Jaime
Pichardo, Raul
Rodriguez Delgado, Luis Carlos
Filippucci, Emilio
Cipolletta, Edoardo
Serban, Teodora
Cirstoiu, Catalin
Vreju, Florentin Ananu
Grecu, Dan
Mouterde, Gaël
Govoni, Marcello
Punzi, Leonardo
Damjanov, Nemanja S.
Keen, Helen Isobel
Bruyn, George A.W.
Terslev, Lene
D'agostino, Maria Antonietta
Scirè, Carlo Alberto
Iagnocco, Annamaria
Filippou, Georgios
Scanu, Anna
Adinolfi, Antonella
Toscano, Carmela
Gambera, Dario
Largo, Raquel
Naredo, Esperanza
Calvo, Emilio
Herrero-Beaumont, Gabriel
Zufferey, Pascal
Bonjour, Christel Madelaine
Maccarter, Daryl K.
Makman, Stanley
Weber, Zachary
Figus, Fabiana
Möller, Ingrid
Gutierrez, Marwin
Pineda, Carlos
Clavijo Cornejo, Denise
Garcia, Hector
Ilizaliturri, Victor
Mendoza Torres, Jaime
Pichardo, Raul
Rodriguez Delgado, Luis Carlos
Filippucci, Emilio
Cipolletta, Edoardo
Serban, Teodora
Cirstoiu, Catalin
Vreju, Florentin Ananu
Grecu, Dan
Mouterde, Gaël
Govoni, Marcello
Punzi, Leonardo
Damjanov, Nemanja S.
Keen, Helen Isobel
Bruyn, George A.W.
Terslev, Lene
D'agostino, Maria Antonietta
Scirè, Carlo Alberto
Iagnocco, Annamaria
Source :
Filippou , G , Scanu , A , Adinolfi , A , Toscano , C , Gambera , D , Largo , R , Naredo , E , Calvo , E , Herrero-Beaumont , G , Zufferey , P , Bonjour , C M , Maccarter , D K , Makman , S , Weber , Z , Figus , F , Möller , I , Gutierrez , M , Pineda , C , Clavijo Cornejo , D , Garcia , H , Ilizaliturri , V , Mendoza Torres , J , Pichardo , R , Rodriguez Delgado , L C , Filippucci , E , Cipolletta , E , Serban , T , Cirstoiu , C , Vreju , F A , Grecu , D , Mouterde , G , Govoni , M , Punzi , L , Damjanov , N S , Keen , H I , Bruyn , G A W , Terslev , L , D'agostino , M A , Scirè , C A & Iagnocco , A 2021 , ' Criterion validity of ultrasound in the identification of calcium pyrophosphate crystal deposits at the knee : an OMERACT ultrasound study ' , Annals of the Rheumatic Diseases , vol. 80 , no. 2 , pp. 261-267 .
Publication Year :
2021

Abstract

Objective To evaluate the discriminatory ability of ultrasound in calcium pyrophosphate deposition disease (CPPD), using microscopic analysis of menisci and knee hyaline cartilage (HC) as reference standard. Methods Consecutive patients scheduled for knee replacement surgery, due to osteoarthritis (OA), were enrolled. Each patient underwent ultrasound examination of the menisci and HC of the knee, scoring each site for presence/absence of CPPD. Ultrasound signs of inflammation (effusion, synovial proliferation and power Doppler) were assessed semiquantitatively (0-3). The menisci and condyles, retrieved during surgery, were examined microscopically by optical light microscopy and by compensated polarised microscopy. CPPs were scored as present/absent in six different samples from the surface and from the internal part of menisci and cartilage. Ultrasound and microscopic analysis were performed by different operators, blinded to each other's findings. Results 11 researchers from seven countries participated in the study. Of 101 enrolled patients, 68 were included in the analysis. In 38 patients, the surgical specimens were insufficient. The overall diagnostic accuracy of ultrasound for CPPD was of 75% -sensitivity of 91% (range 71%-87% in single sites) and specificity of 59% (range 68%-92%). The best sensitivity and specificity were obtained by assessing in combination by ultrasound the medial meniscus and the medial condyle HC (88% and 76%, respectively). No differences were found between patients with and without CPPD regarding ultrasound signs of inflammation. Conclusion Ultrasound demonstrated to be an accurate tool for discriminating CPPD. No differences were found between patents with OA alone and CPPD plus OA regarding inflammation.

Details

Database :
OAIster
Journal :
Filippou , G , Scanu , A , Adinolfi , A , Toscano , C , Gambera , D , Largo , R , Naredo , E , Calvo , E , Herrero-Beaumont , G , Zufferey , P , Bonjour , C M , Maccarter , D K , Makman , S , Weber , Z , Figus , F , Möller , I , Gutierrez , M , Pineda , C , Clavijo Cornejo , D , Garcia , H , Ilizaliturri , V , Mendoza Torres , J , Pichardo , R , Rodriguez Delgado , L C , Filippucci , E , Cipolletta , E , Serban , T , Cirstoiu , C , Vreju , F A , Grecu , D , Mouterde , G , Govoni , M , Punzi , L , Damjanov , N S , Keen , H I , Bruyn , G A W , Terslev , L , D'agostino , M A , Scirè , C A & Iagnocco , A 2021 , ' Criterion validity of ultrasound in the identification of calcium pyrophosphate crystal deposits at the knee : an OMERACT ultrasound study ' , Annals of the Rheumatic Diseases , vol. 80 , no. 2 , pp. 261-267 .
Notes :
English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1322766949
Document Type :
Electronic Resource