Back to Search Start Over

What Is the Diagnostic Performance of Conventional Radiographs and Clinical Reassessment Compared With HR-pQCT Scaphoid Fracture Diagnosis?

Authors :
Daniels, Anne M
Kranendonk, Josephine
Wyers, Caroline E
Janzing, Heinrich M J
Sassen, Sander
van Rietbergen, Bert
Geusens, Piet P M M
Kaarsemaker, Sjoerd
Hannemann, Pascal F W
Poeze, Martijn
van den Bergh, Joop P
Daniels, Anne M
Kranendonk, Josephine
Wyers, Caroline E
Janzing, Heinrich M J
Sassen, Sander
van Rietbergen, Bert
Geusens, Piet P M M
Kaarsemaker, Sjoerd
Hannemann, Pascal F W
Poeze, Martijn
van den Bergh, Joop P
Source :
Clinical Orthopaedics and Related Research vol.481 (2023) nr.1 p.97-104 [ISSN 0009-921X]
Publication Year :
2023

Abstract

BACKGROUND: Conventional radiographs and clinical reassessment are considered guides in managing clinically suspected scaphoid fractures. This is a unique study as it assessed the value of conventional radiographs and clinical reassessment in a cohort of patients, all of whom underwent additional imaging, regardless of the outcome of conventional radiographs and clinical reassessment.QUESTIONS/PURPOSES: (1) What is the diagnostic performance of conventional radiographs in patients with a clinically suspected scaphoid fracture compared with high-resolution peripheral quantitative CT (HR-pQCT)? (2) What is the diagnostic performance of clinical reassessment in patients with a clinically suspected scaphoid fracture compared with HR-pQCT? (3) What is the diagnostic performance of conventional radiographs and clinical reassessment combined compared with HR-pQCT?METHODS: Between December 2017 and October 2018, 162 patients with a clinically suspected scaphoid fracture presented to the emergency department (ED). Forty-six patients were excluded and another 25 were not willing or able to participate, which resulted in 91 included patients. All patients underwent conventional radiography in the ED and clinical reassessment 7 to 14 days later, together with CT and HR-pQCT. The diagnostic performance characteristics and accuracy of conventional radiographs and clinical reassessment were compared with those of HR-pQCT for the diagnosis of fractures since this was proven to be superior to CT scaphoid fracture detection. The cohort included 45 men and 46 women with a median (IQR) age of 52 years (29 to 67). Twenty-four patients with a median age of 44 years (35 to 65) were diagnosed with a scaphoid fracture on HR-pQCT.RESULTS: When compared with HR-pQCT, conventional radiographs alone had a sensitivity of 67% (95% CI 45% to 84%), specificity of 85% (95% CI 74% to 93%), positive predictive value (PPV) of 62% (95% CI 46% to 75%), negative predictive value (N

Details

Database :
OAIster
Journal :
Clinical Orthopaedics and Related Research vol.481 (2023) nr.1 p.97-104 [ISSN 0009-921X]
Notes :
DOI: 10.1097/CORR.0000000000002310, English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1363325825
Document Type :
Electronic Resource