Back to Search Start Over

Micro cone beam computed tomography for sensitive assessment of radiation-induced late lung toxicity in preclinical models

Authors :
Berlo, D. van
Khmelinskii, A.
Gasparini, A.
Salguero, F.J.
Floot, B.
Wit, N. de
Ven, M. van de
Song, J.Y.
Coppes, R.P.
Verheij, M.
Sonke, J.J.
Vens, C.
Berlo, D. van
Khmelinskii, A.
Gasparini, A.
Salguero, F.J.
Floot, B.
Wit, N. de
Ven, M. van de
Song, J.Y.
Coppes, R.P.
Verheij, M.
Sonke, J.J.
Vens, C.
Source :
Radiotherapy and Oncology; 17; 24; 0167-8140; 138; ~Radiotherapy and Oncology~17~24~~~0167-8140~~138~~
Publication Year :
2019

Abstract

Item does not contain fulltext<br />BACKGROUND AND PURPOSE: Preclinical models are much needed to assess the effect of novel radio-sensitizers or mitigators on radiation dose limiting lung toxicity. Albeit showing radiation-induced lung pathologies, current mouse models lack the sensitivity to do so. Using micro image-guided radiotherapy (microIGRT) techniques, we aimed to establish murine models which enable the sensitive detection of lung damage aggravation and characterized functional, radiological and histological responses. MATERIALS AND METHODS: Right lungs of C57Bl/6J mice were irradiated using microIGRT with doses from 15 to 27Gy and with 21Gy and cisplatin as a radio-sensitizer in a second study. Mice were sacrificed for histological and pathological assessment at different time-points post-IR. Lung density was determined using the integrated micro cone-beam CT (microCBCT). Lung function was measured by double-chamber-plethysmography. RESULTS: microIGRT resulted in accurate deposition of the radiation dose in the right lung only as determined by H2AX staining. Lung fibrosis was confirmed by pathological assessments and increased significantly at 21Gy as determined by automated quantification of histochemical analyses. Lung function was affected in a dose-dependent manner. microCBCT-determined lung densities increased significantly over time in the irradiated lungs and showed a strong radiation dose-dependence. Importantly, the microCBCT analyses allowed the detection of additional lung damage caused by 3Gy dose increments or by the combination with cisplatin. CONCLUSION: microCBCT after right lung microIGRT enables the sensitive detection of effects inflicted by relative small dose increments or radio-sensitizers. Our preclinical model therefore facilitates the determination of lung damage exacerbation for the safety assessment of novel RT-drug combinations.

Details

Database :
OAIster
Journal :
Radiotherapy and Oncology; 17; 24; 0167-8140; 138; ~Radiotherapy and Oncology~17~24~~~0167-8140~~138~~
Publication Type :
Electronic Resource
Accession number :
edsoai.on1366807447
Document Type :
Electronic Resource