Back to Search
Start Over
Impact of membranous septum length on pacemaker need with different transcatheter aortic valve replacement systems:The INTERSECT registry
- Source :
- Hokken , T W , Muhemin , M , Okuno , T , Veulemans , V , Lopes , B B , Beneduce , A , Vittorio , R , Ooms , J F , Adrichem , R , Neleman , T , Kardys , I , Daemen , J , Chieffo , A , Montorfano , M , Cavalcante , J , Zeus , T , Pilgrim , T , Toggweiler , S & Van Mieghem , N M 2022 , ' Impact of membranous septum length on pacemaker need with different transcatheter aortic valve replacement systems : The INTERSECT registry ' , Journal of Cardiovascular Computed Tomography , vol. 16 , no. 6 , pp. 524-530 .
- Publication Year :
- 2022
-
Abstract
- Background: New permanent pacemaker implantation (new-PPI) remains a compelling issue after Transcatheter Aortic Valve Replacement (TAVR). Previous studies reported the relationship between a short MS length and the new-PPI post-TAVR with a self-expanding THV. However, this relationship has not been investigated in different currently available THV. Therefore, the aim of this study was to investigate the association between membranous septum (MS)-length and new-PPI after TAVR with different Transcatheter Heart Valve (THV)-platforms. Methods: We included patients with a successful TAVR-procedure and an analyzable pre-procedural multi-slice computed tomography. MS-length was measured using a standardized methodology. The primary endpoint was the need for new-PPI within 30 days after TAVR. Results: In total, 1811 patients were enrolled (median age 81.9 years [IQR 77.2–85.4], 54% male). PPI was required in 275 patients (15.2%) and included respectively 14.2%, 20.7% and 6.3% for Sapien3, Evolut and ACURATE-THV(p < 0.01). Median MS-length was significantly shorter in patients with a new-PPI (3.7 mm [IQR 2.2–5.1] vs. 4.1 mm [IQR 2.8–6.0], p = <0.01). Shorter MS-length was a predictor for PPI in patients receiving a Sapien3 (OR 0.87 [95% CI 0.79–0.96], p = <0.01) and an Evolut-THV (OR 0.91 [95% CI 0.84–0.98], p = 0.03), but not for an ACURATE-THV (OR 0.99 [95% CI 0.79–1.21], p = 0.91). By multivariable analysis, first-degree atrioventricular-block (OR 2.01 [95% CI 1.35–3.00], p = <0.01), right bundle branch block (OR 8.33 [95% CI 5.21–13.33], p = <0.01), short MS-length (OR 0.89 [95% CI 0.83–0.97], p < 0.01), annulus area (OR 1.003 [95% CI 1.001–1.005], p = 0.04), NCC implantation depth (OR 1.13 [95% CI 1.07–1.19] and use of Evolut-THV(OR 1.54 [95% CI 1.03–2.27], p = 0.04) were associated with new-PPI. Conclusion: MS length was an independent predictor for PPI across different THV platforms, except for the ACURATE-THV. Based on our stu
Details
- Database :
- OAIster
- Journal :
- Hokken , T W , Muhemin , M , Okuno , T , Veulemans , V , Lopes , B B , Beneduce , A , Vittorio , R , Ooms , J F , Adrichem , R , Neleman , T , Kardys , I , Daemen , J , Chieffo , A , Montorfano , M , Cavalcante , J , Zeus , T , Pilgrim , T , Toggweiler , S & Van Mieghem , N M 2022 , ' Impact of membranous septum length on pacemaker need with different transcatheter aortic valve replacement systems : The INTERSECT registry ' , Journal of Cardiovascular Computed Tomography , vol. 16 , no. 6 , pp. 524-530 .
- Notes :
- application/pdf, English
- Publication Type :
- Electronic Resource
- Accession number :
- edsoai.on1376785765
- Document Type :
- Electronic Resource