Back to Search Start Over

Electronic neutron personal dosemeters: their performance in mixed radiation fields in nuclear power plants

Authors :
Luszik-Bhadra, M.
Bartlett, D.
Boschung, M.
Coeck, M.
Curzio, G.
Derdau, D.
d'Errico, F.
Fiechtner, A.
Itié, C.
Kyllönen, J.-E
Lacoste, V.
Lahaye, T.
Lindborg, L.
Molinos, C.
Reginatto, M.
Schuhmacher, H.
Tanner, R.
Vanhavere, F.
Luszik-Bhadra, M.
Bartlett, D.
Boschung, M.
Coeck, M.
Curzio, G.
Derdau, D.
d'Errico, F.
Fiechtner, A.
Itié, C.
Kyllönen, J.-E
Lacoste, V.
Lahaye, T.
Lindborg, L.
Molinos, C.
Reginatto, M.
Schuhmacher, H.
Tanner, R.
Vanhavere, F.
Publication Year :
2017

Abstract

This work describes spectral distributions of neutrons obtained as function of energy and direction at four workplace fields at the Krümmel reactor in Germany. Values of personal dose equivalent Hp(10) and effective dose E are determined for different directions of a person's orientation in these fields and readings of personal neutron dosemeters—especially electronic dosemeters—are discussed with respect to Hp(10) and E

Details

Database :
OAIster
Notes :
English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1379356123
Document Type :
Electronic Resource